M38039FFHFP#U0 Renesas Electronics America, M38039FFHFP#U0 Datasheet - Page 78

IC 740 MCU FLASH 60K 64QFP

M38039FFHFP#U0

Manufacturer Part Number
M38039FFHFP#U0
Description
IC 740 MCU FLASH 60K 64QFP
Manufacturer
Renesas Electronics America
Series
740/38000r
Datasheet

Specifications of M38039FFHFP#U0

Core Processor
740
Core Size
8-Bit
Speed
16.8MHz
Connectivity
SIO, UART/USART
Peripherals
PWM, WDT
Number Of I /o
56
Program Memory Size
60KB (60K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 16x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 85°C
Package / Case
64-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
M38039FFHFP#U0M38039FFHFP
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
M38039FFHFP#U0
Manufacturer:
MITSUBISHI
Quantity:
360
Company:
Part Number:
M38039FFHFP#U0
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Company:
Part Number:
M38039FFHFP#U0
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
3803 Group (Spec.H)
Rev.3.11
REJ03B0017-0311
Full Status Check
By performing full status check, it is possible to know the
execution results of erase and program operations. Figure.71
shows a full status check flowchart and the action to be taken
when each error occurs.
Fig 71. Full status check flowchart and remedial procedure for errors
Apr 5, 2006
Note: When one of SR5 and SR4 is set to “1”, none of the read array, program,
End (block erase, program)
and block erase commands is accepted. Execute the clear status register
command (50
Read status register
SR5 = “1”?
SR5 = “0”?
SR4 = “0”?
SR4 = “1”
and
Page 76 of 113
YES
YES
NO
16
) before executing these commands.
YES
NO
NO
sequence error
Program error
Erase error
Command
Execute the clear status register command (50
to clear the status register. Try performing the
operation one more time after confirming that the
command is entered correctly.
Should an erase error occur, the block in error
cannot be used.
Should a program error occur, the block in error
cannot be used.