HD6413003TF16 Renesas Electronics America, HD6413003TF16 Datasheet - Page 478

IC H8 MCU ROMLESS QFP112

HD6413003TF16

Manufacturer Part Number
HD6413003TF16
Description
IC H8 MCU ROMLESS QFP112
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD6413003TF16

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
DMA, PWM, WDT
Number Of I /o
50
Program Memory Type
ROMless
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
112-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413003TF16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413003TF16V
Manufacturer:
ITT
Quantity:
12 000
Part Number:
HD6413003TF16V
Manufacturer:
RENESAS
Quantity:
36
Part Number:
HD6413003TF16V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Receiving Serial Data (Asynchronous Mode): Figure 13-7 shows a sample flowchart for
receiving serial data and indicates the procedure to follow.
No
No
Clear RE bit to 0 in SCR
Read RDRF flag in SSR
RDRF flag to 0 in SSR
and FER flags in SSR
from RDR, and clear
Read ORER, PER,
Read receive data
Start receiving
PER
ORER = 1?
RDRF = 1?
receiving?
Finished
Initialize
Figure 13-7 Sample Flowchart for Receiving Serial Data (1)
End
RER
No
Yes
Yes
(continued on next page)
Yes
Error handling
5
1
2
4
3
458
1.
2., 3.
4.
5.
SCI initialization: the receive data function of
the RxD pin is selected automatically.
detection: if a receive error occurs, read the
ORER, PER, and FER flags in SSR to identify
the error. After executing the necessary error
handling, clear the ORER, PER, and FER
flags all to 0. Receiving cannot resume if any
of the ORER, PER, and FER flags remains
set to 1. When a framing error occurs, the
RxD pin can be read to detect the break state.
SCI status check and receive data read: read
SSR, check that RDRF is set to 1, then read
receive data from RDR and clear the RDRF
flag to 0. Notification that the RDRF flag has
changed from 0 to 1 can also be given by the
RXI interrupt.
To continue receiving serial data: check the
RDRF flag, read RDR, and clear the RDRF
flag to 0 before the stop bit of the current
frame is received. If the DMAC is activated
by an RXI interrupt to read the RDR value,
the RDRF flag is cleared automatically.
Receive error handling and break