HD6413003TF16 Renesas Electronics America, HD6413003TF16 Datasheet - Page 69

IC H8 MCU ROMLESS QFP112

HD6413003TF16

Manufacturer Part Number
HD6413003TF16
Description
IC H8 MCU ROMLESS QFP112
Manufacturer
Renesas Electronics America
Series
H8® H8/300Hr
Datasheet

Specifications of HD6413003TF16

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
DMA, PWM, WDT
Number Of I /o
50
Program Memory Type
ROMless
Ram Size
512 x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
112-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6413003TF16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6413003TF16V
Manufacturer:
ITT
Quantity:
12 000
Part Number:
HD6413003TF16V
Manufacturer:
RENESAS
Quantity:
36
Part Number:
HD6413003TF16V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
2.8.2 Program Execution State
In this state the CPU executes program instructions in normal sequence.
2.8.3 Exception-Handling State
The exception-handling state is a transient state that occurs when the CPU alters the normal
program flow due to a reset, interrupt, or trap instruction. The CPU fetches a starting address from
the exception vector table and branches to that address. In interrupt and trap exception handling
the CPU references the stack pointer (ER7) and saves the program counter and condition code
register.
Types of Exception Handling and Their Priority: Exception handling is performed for resets,
interrupts, and trap instructions. Table 2-14 indicates the types of exception handling and their
priority. Trap instruction exceptions are accepted at all times in the program execution state.
Table 2-14 Exception Handling Types and Priority
Priority Type of Exception Detection Timing
High
Low
Note: * Interrupts are not detected at the end of the ANDC, ORC, XORC, and LDC instructions, or
Figure 2-12 classifies the exception sources. For further details about exception sources, vector
numbers, and vector addresses, see section 4, Exception Handling, and section 5, Interrupt
Controller.
immediately after reset exception handling.
Reset
Interrupt
Trap instruction
Synchronized with clock
End of instruction
execution or end of
exception handling*
When TRAPA instruction
is executed
49
Start of Exception Handling
Exception handling starts immediately
when
When an interrupt is requested,
exception handling starts at the end of
the current instruction or current
exception-handling sequence
Exception handling starts when a trap
(TRAPA) instruction is executed
RES changes from low to high