DRT2-ID32BV-1 Omron, DRT2-ID32BV-1 Datasheet - Page 116

no-image

DRT2-ID32BV-1

Manufacturer Part Number
DRT2-ID32BV-1
Description
32 In Vert MIL Connector PNP
Manufacturer
Omron
Datasheet

Specifications of DRT2-ID32BV-1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
IN Window
Maintenance Information Window
Note
1. The Load Disconnection Detection and Load Disconnection Detection His-
2. The Load Short-circuit Detection and Load Short-circuit Detection History
Terminals are listed in numerical order.
Comment
Maintenance
Counter
Load Disconnection
Detection
Load Short-circuit
Detection
Load Disconnection
Detection History
Load Short-circuit
Detection History
Comment
Maintenance
Counter
tory functions are supported by the following models:
DRT2-OD@@SLH(-1) and DRT2-MD32SLH(-1) Screw-less Clamp Termi-
nals
functions are supported by the following models:
DRT2-MD16S(-1) Sensor Connector Terminals and DRT2-OD16SLH(-1)
Screw-less Clamp Terminals.
Item
Item
Displays up to 32 characters of text set as the output comment
for each output.
Displays the maintenance counter for each output. If the main-
tenance counter exceeds the threshold value, a warning icon
will be displayed on the left side of the output’s No. column.
Total ON Time Monitor: Units = seconds
Contact Operation Counter: Units = operations
If load disconnection detection (off-wire detection) is enabled,
either Not off-wire or Off-wire will be displayed.
If off-wire detection is disabled, --- will be displayed.
If load short-circuit detection is enabled, either No short-circuit
or Short-circuit will be displayed.
If short-circuit detection is disabled, --- will be displayed.
Records information when a disconnection occurred. When
load disconnections are not being detected, --- will be dis-
played.
Records information when a short-circuit occurs. When load
short-circuits are not being detected, --- will be displayed.
Displays up to 32 characters of text set as the input comment
for each input.
Displays the maintenance counter for each input. If the main-
tenance counter exceeds the threshold value, a warning icon
will be displayed on the left side of the input’s No. column.
Total ON Time Monitor: Units = seconds
Contact Operation Counter: Units = operations
Description
Description
Section 5-4
95

Related parts for DRT2-ID32BV-1