Overview of Analog Slaves
7-1
7-1-1
7-1-2
Analog Input Terminals
292
Slave
Model
Analog points
Input range (signals)
AD conversion cycle
AD conversion data
Resolution
Unit power supply
Communications
power supply current
consumption
Overall
accuracy
Overview of Analog Slaves
25°C
−10 to
55°C
DRT2 Analog Slaves
Comparison of DRT1 and DRT2 Functions
DRT1-AD04
4 inputs
0 to 5 V, 1 to 5 V, 0 to
10 V,–10 to 10 V, 0 to
20 mA, 4 to 20 mA
2 ms/point (8 ms/4
points or 4 ms/2 points)
0 to 5 V, 1 to 5 V, 0 to
10 V, 0 to 20 mA, 4 to
20 mA: 0000 to 1770
hex
–10 to 10 V: 8BB8 to
0BB8 hex
Note Signed binary
1/6,000 (full scale)
Supplied by local power supply terminal.
30 mA max.
Voltage input:
0 to 55°C:
Voltage input:
FS
This section provides an overview of Analog Slaves, including details on func-
tions and setting methods for each Slave.
Compared with the previous DRT1 Analog Slaves, DRT2 Analog Slaves com-
bine the maintenance functions (network power voltage monitor and Unit con-
duction time monitor) of DRT2-series Slaves with various functions of Analog
Slaves (such as scaling and peak/bottom hold). Analog Input Terminals are
also able to internally perform math on analog input values, which previously
required ladder programming in the Master CPU Unit. Analog data or temper-
ature data can be selected from the six values obtained from math operations
and allocated in the Master in combination with Generic Status Flags or other
status information. (Status information alone can also be allocated.) The Con-
figurator or explicit messages can be used to allocate data in the Master, and
to set Analog Slave functions and perform monitoring.
±
±
0.3% FS; Current input:
0.6% FS; Current input:
DRT1 Series
DRT1-AD04H
0 to 5 V, 1 to 5 V, 0 to
10 V, 0 to 20 mA, 4 to
20 mA (–10 to 10 V not
supported)
250 ms/ 4 points
0 to 5 V, 1 to 5 V, 0 to
10 V, 0 to 20 mA, 4 to
20 mA: 0000 to 7530
hex
Note Two’s comple-
1/30,000 (full scale)
ment
±
±
0.4% FS
0.8%
DRT2-AD04
0 to 5 V, 1 to 5 V, 0 to
10 V, –10 to 10 V, 0 to
20 mA, 4 to 20 mA
By setting the number
of conversion points (1
to 4 points), the con-
version cycle can be
shortened (e.g., 4
points: 4 ms max.)
Note The conversion
0 to 5 V, 1 to 5 V, 0 to
10 V, 0 to 20 mA, 4 to
20 mA: 0000 to 1770
hex
–10 to 10 V: F448 to
0BB8 hex
Note Two’s comple-
1/6,000 (full scale)
Supplied by communications power supply.
90 mA max.
−10 to 55°C:
Voltage input:
FS
cycle will be
slightly differ-
ent when the
math opera-
tions are used.
ment
±
0.6% FS; Current input:
DRT2 Series
DRT2-AD04H
0 to 5 V, 1 to 5 V, 0 to
10 V, 0 to 20 mA, 4 to
20 mA (–10 to 10 V not
supported)
250 ms/ 4 points
0 to 5 V, 1 to 5 V, 0 to
10 V, 0 to 20 mA, 4 to
20 mA: 0000 to 7530
hex
Note Two’s comple-
1/30,000 (full scale)
70 mA max.
ment
Section 7-1
±
0.8%