DRT2-ID32BV-1 Omron, DRT2-ID32BV-1 Datasheet - Page 317

no-image

DRT2-ID32BV-1

Manufacturer Part Number
DRT2-ID32BV-1
Description
32 In Vert MIL Connector PNP
Manufacturer
Omron
Datasheet

Specifications of DRT2-ID32BV-1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Overview of Analog Slaves
DRT2-DA02 Analog Output Terminals
DRT2-TS04T/DRT2-TS04P Temperature Input Terminals
296
Scaling
Peak/bottom hold
Top/valley hold
Rate of change
Comparator
Off-wire detection
User adjustment
Cumulative counter
Last maintenance date
Scaling
User adjustment
Cumulative counter (main-
tenance function)
Error output value setting
Last maintenance date
Moving average
Scaling
Peak/bottom hold
Top/valley hold
Rate of change
Function
Function
Function
Performs scaling.
Scaling allows conversion of values between 0 and 6,000
into values using the industry unit required by the user. It
reduces the number of operations required in ladder pro-
gramming in the Master.
Adjusts the output when an offset occurs in the output volt-
age or current.
Calculates an approximation to the integral of analog output
values over time.
Sets the value output when a communications error occurs
for each output.
Records the date of the last maintenance in the Unit.
Performs scaling.
Scaling allows conversion of values between 0 and 6,000 (0
to 30,000 in the DRT2-AD04H) into values using the indus-
try unit required by the user. It reduces the number of oper-
ations requiring ladder programming in the Master CPU
Unit. Scaling also supports an offset function for compen-
sating for mounting errors in sensors and other devices.
Holds the maximum and minimum analog input values.
Holds the top and valley values for analog input values.
Calculates the rate of change for analog input values.
Compares the analog input value or an analog value after
math processing (value for peak, bottom, top, valley, rate of
change) with the four set values HH, H, L, and LL, and indi-
cates the result with the Analog Status Flags.
Detects disconnections of analog inputs. (Valid only for the
input ranges 4 to 20 mA and 1 to 5 V)
Adjusts the input when an offset occurs in the input voltage
or current.
Calculates an approximation to the integral of analog input
values over time.
Records the date of the last maintenance in the Unit.
Calculates the average of the past eight temperature
input values, and produces a stable input value even
when the input value is unsteady.
Performs scaling.
Scaling allows input values to be converted using default
upper and lower limits that can be set independently in
each Unit. The scaling function reduces the number of
operations requiring ladder programming in the Master
CPU Unit. Scaling also provides an offset function to
compensate for mounting errors in sensors and other
devices.
Holds the maximum and minimum temperature input val-
ues.
Holds the top and valley temperature input values.
Calculates the rate of change of temperature input val-
ues.
Details
Details
Details
Disabled (0 to 6,000)
Disabled
Disabled
Low limit
2002/1/1
0 to 6,000 (DRT2-AD04)
0 to 28,000 (DRT2-AD04H)
Disabled
Disabled
Disabled
Disabled
Enabled
Disabled
Disabled
2002/1/1 (DRT2-AD04)
2004/1/1 (DRT2-AD04H)
Moving average disabled.
Disabled
0 to 28, 000
Disabled
Disabled
Disabled
Default
Default
Default
Section 7-1