DRT2-ID32BV-1 Omron, DRT2-ID32BV-1 Datasheet - Page 503

no-image

DRT2-ID32BV-1

Manufacturer Part Number
DRT2-ID32BV-1
Description
32 In Vert MIL Connector PNP
Manufacturer
Omron
Datasheet

Specifications of DRT2-ID32BV-1

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
482
DeviceNet Explicit Messages
Analog
Data 1 Allo-
cation
Selection
Analog
Data 2 Allo-
cation
Selection
Function
Setting
Scaling
Type Set-
ting
Scaling
Point 1 Set-
ting
Scaling
Point 2 Set-
ting
Offset
Compensa-
tion
Maximum
Value Read
Minimum
Value Read
Peak Value
Read
Bottom
Value Read
message
Explicit
/write
Write/
Read
Write/
Read
Write/
Read
Write/
Read
Write/
Read
Write/
Read
Write/
Read
Read/
Reset
Read/
Reset
Read The peak value is held
Read The bottom value is held
Read
Selects the data allo-
cated to Analog Data 1.
Analog input value: 0;
Peak value: 1;
Bottom value: 2;
Top value: 3;
Valley value: 4;
Rate of change value: 5
Selects the data allo-
cated to Analog Data 2.
Analog input value: 0;
Peak value: 1;
Bottom value: 2;
Top value: 3;
Valley value: 4;
Rate of change value: 5
Sets each function.
Bit status:
ON: Enabled,
OFF: Disabled
Moving average: 0;
Scaling: 1;
Peak/bottom hold: 2;
Top/valley hold: 3;
Comparator: 4;
Cumulative counter: 5;
Rate of change: 6
Default scaling: 0:
User scaling: 1
Sets an analog value as
the 0% value for user
scaling.
Sets an analog value as
the 100% value for user
scaling.
Compensates for scal-
ing errors with an offset
value.
Reads the maximum
value after power is
turned ON.
Reads the minimum
value after power is
turned ON.
and read.
and read.
Function
Service
Write:
10 Hex
Read:
0E Hex
Write:
10 Hex
Read:
0E Hex
Write:
10 Hex
Read:
0E Hex
Write:
10 Hex
Read:
0E Hex
Write:
10 Hex
Read:
0E Hex
Write:
10 Hex
Read:
0E Hex
Write:
10 Hex
Read:
0E Hex
Read:
0E Hex
Reset:
35 Hex
Read:
0E Hex
Reset:
35 Hex
0E Hex 0A Hex 01 to 04
0E Hex 0A Hex 01 to 04
code
0A Hex 01 to 04
0A Hex 01 to 04
0A Hex 01 to 04
0A Hex 01 to 04
0A Hex 01 to 04
0A Hex 01 to 04
0A Hex 01 to 04
0A Hex 01 to 04
0A Hex 01 to 04
Class
ID
Hex
Hex
Hex
Hex
Hex
Hex
Hex
Hex
Hex
Hex
Hex
Instance
ID
Command
Attribute ID
68 Hex
69 Hex
6E Hex
6F Hex
70 Hex
71 Hex
72 Hex
73 Hex
74 Hex
75 Hex
76 Hex
Command data
1 byte
1 byte
1 byte
1 byte
2 bytes
(−28000 to
28000)
2 bytes
(−28000 to
28000)
2 bytes
(−28000 to
28000)
---
---
---
---
Data
Appendix A
1 byte
1 byte
1 byte
1 byte
2 bytes
(−28000 to
28000)
2 bytes
(−28000 to
28000)
2 bytes
(−28000 to
28000)
2 bytes
2 bytes
2 bytes
2 bytes
Response