DeviceNet Remote I/O Communications
3-2-2
General-purpose
Slaves and
Environment-resistive
Slaves
36
Description
Method
Configuration
Setting method
with Configurator
Type
I/O Allocations for Smart Slaves
Select up to two types of I/O data, and allocate to user-defined addresses in the Master Unit.
1. Select up to two types of I/O data using the Configurator.
2. Allocate the selected I/O data to user-defined addresses in the Master Unit.
1. In the Master’s Edit Device Parameters Window, select the Smart Slave to be set, and specify the
2. In the Master’s Edit Device Parameters Window, allocate Slave I/O.
Allocation
1,2,3...
connection in the Advanced Setting Window. Select the I/O data (pattern) in the connection path
setting.
Note The above method can be used only if the Master Unit is a CS/CJ-series
2. Specify each
Note: Up to two connections can be specified from
connection path.
DeviceNet Unit. When using a CVM1/CV-series DeviceNet Master Unit, a
C200HX/HG/HE/HS DeviceNet Master Unit, or another company’s Master
Unit, select the I/O data from the pull-down menu for the default connection
path in the Slave’s Edit Device Parameters Window.
DRT2-slave data can be allocated for remote I/O communications with the
Master Unit using any of the following methods.
1. Allocating only real I/O data (default)
2. Allocating real I/O data and Generic Status Flags together
3. Allocating real I/O data and Generic Status Flags independently
1. Specify two connections.
CS/CJ-series Master Units.
Selecting I/O data and allocating to user-defined addresses
Method 2 can be performed by selecting the I/O data and flags from the
pull-down menu for the Slave’s default connection path using the Configu-
rator.
Method 3 can be performed by allocating real I/O data and Generic Status
Flags independently in the Master’s connection path using the Configura-
tor. (This method can be used only with CS/CJ-series Master Units.)
I/O memory
Master CPU Unit
A
E
Data
Smart Slave
B
C
D
A
E
Allocate to user-
defined addresses.
Allocate to user-
defined addresses.
With the Configurator, for
each connection, select
data and allocate to
user-defined addresses.
Section 3-2