EP4CE55F23C8 Altera, EP4CE55F23C8 Datasheet - Page 138

no-image

EP4CE55F23C8

Manufacturer Part Number
EP4CE55F23C8
Description
IC CYCLONE IV FPGA 55K 484FBGA
Manufacturer
Altera
Series
CYCLONE® IV Er

Specifications of EP4CE55F23C8

Number Of Logic Elements/cells
55856
Number Of Labs/clbs
3491
Total Ram Bits
2340000
Number Of I /o
324
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CE55F23C8
Manufacturer:
ALTERA
Quantity:
784
Part Number:
EP4CE55F23C8
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8
Manufacturer:
ALTERA
0
Part Number:
EP4CE55F23C8L
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA
Quantity:
364
Part Number:
EP4CE55F23C8LN
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA
0
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
Quantity:
852
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
Quantity:
20 000
Part Number:
EP4CE55F23C8N
0
6–30
Figure 6–14. BLVDS Topology with Cyclone IV Devices Transmitters and Receivers
Cyclone IV Device Handbook, Volume 1
100 kΩ
100 kΩ
GND
f
f
R
1
T
V
CC
Figure 6–14
pairs.
The BLVDS I/O standard is supported on the top, bottom, and right I/O banks of
Cyclone IV devices. The BLVDS transmitter uses two single-ended output buffers
with the second output buffer programmed as inverted, while the BLVDS receiver
uses a true LVDS input buffer. The transmitter and receiver share the same pins. An
output-enabled (OE) signal is required to tristate the output buffers when the LVDS
input buffer receives a signal.
For more information, refer to the
Designing with BLVDS
The BLVDS bidirectional communication requires termination at both ends of the bus
in BLVDS. The termination resistor (R
which in turn depends on the loading on the bus. Increasing the load decreases the
bus differential impedance. With termination at both ends of the bus, termination is
not required between the two signals at the input buffer. A single series resistor (R
required at the output buffer to match the output buffer impedance to the
transmission line impedance. However, this series resistor affects the voltage swing at
the input buffer. The maximum data rate achievable depends on many factors.
Altera recommends that you perform simulation using the IBIS model while
considering factors such as bus loading, termination values, and output and input
buffer location on the bus to ensure that the required performance is achieved.
For more information about BLVDS interface support in Altera devices, refer to
AN 522: Implementing Bus LVDS Interface in Supported Altera Device
50 Ω
50
Ω
Output
Data
shows a typical BLVDS topology with multiple transmitter and receiver
Input
Data
50 Ω
50 Ω
Output
Data
Cyclone IV Device Datasheet
Input
Data
T
) must match the bus differential impedance,
50 Ω
50 Ω
Output
Data
Chapter 6: I/O Features in Cyclone IV Devices
© December 2010 Altera Corporation
Input
Data
50 Ω
50 Ω
High-Speed I/O Standards Support
chapter.
Families.
V
CC
100 kΩ
100 k
GND
R
T
Ω
S
) is