EP4CE55F23C8 Altera, EP4CE55F23C8 Datasheet - Page 236

no-image

EP4CE55F23C8

Manufacturer Part Number
EP4CE55F23C8
Description
IC CYCLONE IV FPGA 55K 484FBGA
Manufacturer
Altera
Series
CYCLONE® IV Er

Specifications of EP4CE55F23C8

Number Of Logic Elements/cells
55856
Number Of Labs/clbs
3491
Total Ram Bits
2340000
Number Of I /o
324
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CE55F23C8
Manufacturer:
ALTERA
Quantity:
784
Part Number:
EP4CE55F23C8
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8
Manufacturer:
ALTERA
0
Part Number:
EP4CE55F23C8L
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA
Quantity:
364
Part Number:
EP4CE55F23C8LN
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA
0
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
Quantity:
852
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
Quantity:
20 000
Part Number:
EP4CE55F23C8N
0
8–70
Remote System Upgrade Mode
Cyclone IV Device Handbook, Volume 1
In remote update mode, Cyclone IV devices load the factory configuration image after
power up. The user-defined factory configuration determines the application
configuration to be loaded and triggers a reconfiguration cycle. The factory
configuration can also contain application logic.
When used with configuration memory, the remote update mode allows an
application configuration to start at any flash sector boundary. Additionally, the
remote update mode features a user watchdog timer that can detect functional errors
in an application configuration.
Remote Update Mode
In AS configuration scheme, when a Cyclone IV device is first powered up in remote
update, it loads the factory configuration located at address
boot_address[23:0] = 24b'0. Altera recommends storing the factory
configuration image for your system at boot address 24b'0, which corresponds to the
start address location 0×000000 in the serial configuration device. A factory
configuration image is a bitstream for the Cyclone IV device in your system that is
programmed during production and is the fall-back image when an error occurs. This
image is stored in non-volatile memory and is never updated or modified using
remote access.
When you use the AP configuration in Cyclone IV E devices, the Cyclone IV E device
loads the default factory configuration located at the following address after device
power-up in remote update mode:
boot_address[23:0] = 24'h010000 = 24'b1 0000 0000 0000 0000.
You can change the default factory configuration address to any desired address using
the APFC_BOOT_ADDR JTAG instruction. The factory configuration image is stored in
non-volatile memory and is never updated or modified using remote access. This
corresponds to the default start address location 0×010000 represented in 16-bit
word addressing (or the updated address if the default address is changed) in the
supported parallel flash memory. For more information about the application of the
APFC_BOOT_ADDR JTAG instruction in AP configuration scheme, refer to the
Instructions” on page
8–56.
Chapter 8: Configuration and Remote System Upgrades in Cyclone IV Devices
© December 2010 Altera Corporation
Remote System Upgrade
“JTAG

Related parts for EP4CE55F23C8