EP4CE55F23C8 Altera, EP4CE55F23C8 Datasheet - Page 294

no-image

EP4CE55F23C8

Manufacturer Part Number
EP4CE55F23C8
Description
IC CYCLONE IV FPGA 55K 484FBGA
Manufacturer
Altera
Series
CYCLONE® IV Er

Specifications of EP4CE55F23C8

Number Of Logic Elements/cells
55856
Number Of Labs/clbs
3491
Total Ram Bits
2340000
Number Of I /o
324
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
484-FBGA
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CE55F23C8
Manufacturer:
ALTERA
Quantity:
784
Part Number:
EP4CE55F23C8
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8
Manufacturer:
ALTERA
0
Part Number:
EP4CE55F23C8L
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA
Quantity:
364
Part Number:
EP4CE55F23C8LN
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA
0
Part Number:
EP4CE55F23C8LN
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
Quantity:
852
Part Number:
EP4CE55F23C8N
Manufacturer:
ALTERA
Quantity:
20 000
Part Number:
EP4CE55F23C8N
0
1–14
Deserializer
Cyclone IV Device Handbook, Volume 2
f
1
Actual lock time depends on the transition density of the incoming data and the PPM
difference between the receiver input reference clock and the upstream transmitter
reference clock.
Transition from the LTD state to the LTR state occurs when either of the following
conditions is met:
In automatic lock mode, the switch from LTR to LTD states is indicated by the
assertion of the rx_freqlocked signal and the switch from LTD to LTR states
indicated by the de-assertion of the rx_freqlocked signal.
Manual Lock Mode
State transitions are controlled manually by using rx_locktorefclk and
rx_locktodata ports. The LTR/LTD controller sets the CDR state depending on the
logic level on the rx_locktorefclk and rx_locktodata ports. This mode
provides the flexibility to control the CDR for a reduced lock time compared to the
automatic lock mode. In automatic lock mode, the LTR/LTD controller relies on the
PPM detector and the phase relationship detector to set the CDR in LTR or LTD mode.
The PPM detector and phase relationship detector reaction times can be too long for
some applications that require faster CDR lock time.
In manual lock mode, the rx_freqlocked signal is asserted when the CDR is in LTD
state and de-asserted when CDR is in LTR state. For descriptions of
rx_locktorefclk and rx_locktodata port controls, refer to
page
If you do not enable the optional rx_locktorefclk and rx_locktodata ports,
the Quartus II software automatically configures the LTR/LTD controller in automatic
lock mode.
The recommended transceiver reset sequence varies depending on the CDR lock
mode. For more information about the reset sequence recommendations, refer to the
Reset Control and Power Down for Cyclone IV GX Devices
The deserializer converts received serial data from the receiver input buffer to parallel
8- or 10-bit data. Serial data is assumed to be received from the LSB to the MSB. The
deserializer operates with the high-speed recovered clock from the CDR with the
frequency at half of the serial data rate.
The recovered clock is within the configured part per million (PPM) frequency
threshold setting with respect to the CDR clocks from multipurpose PLL.
Signal detection circuitry indicates the absence of valid signal levels at the receiver
input buffer. This condition is valid for PCI Express (PIPE) mode only. CDR
transitions are not dependent on signal detection circuitry in other modes.
The recovered clock is not within the configured PPM frequency threshold setting
with respect to CDR clocks from multipurpose PLLs.
1–80.
Chapter 1: Cyclone IV Transceivers Architecture
chapter.
© December 2010 Altera Corporation
Table 1–27 on
Receiver Channel Datapath