ATtiny20 Atmel Corporation, ATtiny20 Datasheet - Page 118

no-image

ATtiny20

Manufacturer Part Number
ATtiny20
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny20

Flash (kbytes)
2 Kbytes
Pin Count
14
Max. Operating Frequency
12 MHz
Cpu
8-bit AVR
# Of Touch Channels
5
Hardware Qtouch Acquisition
Yes
Max I/o Pins
12
Ext Interrupts
12
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.12
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8 to 5.5
Operating Voltage (vcc)
1.8 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
4
Input Capture Channels
1
Pwm Channels
3
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATtiny20-CCU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATtiny20-CCUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATtiny20-MMHR
Manufacturer:
ATMEL
Quantity:
20 000
Part Number:
ATtiny20-SSU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny20-XU
Manufacturer:
Atmel
Quantity:
904
15.6
15.6.1
118
Changing Channel or Reference Selection
ATtiny20
ADC Input Channels
For a summary of conversion times, see
Table 15-1.
The MUX and REFS bits in the ADMUX Register are single buffered through a temporary regis-
ter to which the CPU has random access. This ensures that the channels and reference
selection only takes place at a safe point during the conversion. The channel and reference
selection is continuously updated until a conversion is started. Once the conversion starts, the
channel and reference selection is locked to ensure a sufficient sampling time for the ADC. Con-
tinuous updating resumes in the last ADC clock cycle before the conversion completes (ADIF in
ADCSRA is set). Note that the conversion starts on the following rising ADC clock edge after
ADSC is written. The user is thus advised not to write new channel or reference selection values
to ADMUX until one ADC clock cycle after ADSC is written.
If Auto Triggering is used, the exact time of the triggering event can be indeterministic. Special
care must be taken when updating the ADMUX Register, in order to control which conversion
will be affected by the new settings.
If both ADATE and ADEN is written to one, an interrupt event can occur at any time. If the
ADMUX Register is changed in this period, the user cannot tell if the next conversion is based
on the old or the new settings. ADMUX can be safely updated in the following ways:
When updating ADMUX in one of these conditions, the new settings will affect the next ADC
conversion.
When changing channel selections, the user should observe the following guidelines to ensure
that the correct channel is selected:
Condition
First conversion
Normal conversions
Auto Triggered conversions
Free Running conversion
• When ADATE or ADEN is cleared.
• During conversion, minimum one ADC clock cycle after the trigger event.
• After a conversion, before the Interrupt Flag used as trigger source is cleared.
• In Single Conversion mode, always select the channel before starting the conversion. The
• In Free Running mode, always select the channel before starting the first conversion. The
channel selection may be changed one ADC clock cycle after writing one to ADSC. However,
the simplest method is to wait for the conversion to complete before changing the channel
selection.
channel selection may be changed one ADC clock cycle after writing one to ADSC. However,
the simplest method is to wait for the first conversion to complete, and then change the
ADC Conversion Time
Sample & Hold (Cycles from
Start of Conversion)
Table
13.5
1.5
2.5
2
15-1.
Conversion Time (Cycles)
13.5
25
13
14
8235B–AVR–04/11

Related parts for ATtiny20