ATtiny20 Atmel Corporation, ATtiny20 Datasheet - Page 21

no-image

ATtiny20

Manufacturer Part Number
ATtiny20
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny20

Flash (kbytes)
2 Kbytes
Pin Count
14
Max. Operating Frequency
12 MHz
Cpu
8-bit AVR
# Of Touch Channels
5
Hardware Qtouch Acquisition
Yes
Max I/o Pins
12
Ext Interrupts
12
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.12
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8 to 5.5
Operating Voltage (vcc)
1.8 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
4
Input Capture Channels
1
Pwm Channels
3
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATtiny20-CCU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATtiny20-CCUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATtiny20-MMHR
Manufacturer:
ATMEL
Quantity:
20 000
Part Number:
ATtiny20-SSU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny20-XU
Manufacturer:
Atmel
Quantity:
904
6.4.2
6.4.3
8235B–AVR–04/11
Starting from Power-Down Mode
Starting from Idle / ADC Noise Reduction / Standby Mode
Table 6-1.
Notes:
When waking up from Power-Down sleep mode, the supply voltage is assumed to be at a suffi-
cient level and only the oscillator start-up time is counted to ensure the stable operation of the
oscillator. The oscillator start-up time is counted on the selected main clock, and the start-up
time depends on the clock selected. See
Table 6-2.
Notes:
When waking up from Idle, ADC Noise Reduction or Standby Mode, the oscillator is already run-
ning and no oscillator start-up time is introduced.
2. The second step is to count the oscillator start-up time, which ensures that the cali-
3. The last step before releasing the internal reset is to load the calibration and the config-
Reset
64 ms
voltage has reached sufficient levels. The reset start-up time is counted using the inter-
nal 128 kHz oscillator. See
Note that the actual supply voltage is not monitored by the start-up logic. The device
will count until the reset start-up time has elapsed even if the device has reached suffi-
cient supply voltage levels earlier.
brated internal oscillator has reached a stable state before it is used by the other parts
of the system. The calibrated internal oscillator needs to oscillate for a minimum num-
ber of cycles before it can be considered stable. See
oscillator start-up time.
uration values from the Non-Volatile Memory to configure the device properly. The
configuration time is listed in
1. After powering up the device or after a reset the system clock is automatically set to calibrated
2. When the Brown-out Detection is enabled, the reset start-up time is 128 ms after powering up
1. The start-up time is measured in main clock oscillator cycles.
2. When using software BOD disable, the wake-up time from sleep mode will be approximately
Oscillator start-up time
internal 8 MHz oscillator, divided by 8
the device.
60 µs.
Oscillator
6 cycles
Start-up Times when Using the Internal Calibrated Oscillator
Start-up Time from Power-Down Sleep Mode.
6 cycles
Configuration
21 cycles
Table 6-1
Table
6-1.
Table 6-2
Total start-up time
64 ms + 6 oscillator cycles + 21 system clock cycles
for details of reset start-up time.
for details.
Table 6-1
6 oscillator cycles
Total start-up time
for details of the
(1)(2)
ATtiny20
(1)(2)
21