ATtiny20 Atmel Corporation, ATtiny20 Datasheet - Page 86

no-image

ATtiny20

Manufacturer Part Number
ATtiny20
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of ATtiny20

Flash (kbytes)
2 Kbytes
Pin Count
14
Max. Operating Frequency
12 MHz
Cpu
8-bit AVR
# Of Touch Channels
5
Hardware Qtouch Acquisition
Yes
Max I/o Pins
12
Ext Interrupts
12
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
15
Analog Comparators
1
Resistive Touch Screen
No
Temp. Sensor
Yes
Crypto Engine
No
Sram (kbytes)
0.12
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8 to 5.5
Operating Voltage (vcc)
1.8 to 5.5
Fpu
No
Mpu / Mmu
no / no
Timers
2
Output Compare Channels
4
Input Capture Channels
1
Pwm Channels
3
32khz Rtc
No
Calibrated Rc Oscillator
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATtiny20-CCU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATtiny20-CCUR
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
ATtiny20-MMHR
Manufacturer:
ATMEL
Quantity:
20 000
Part Number:
ATtiny20-SSU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
ATtiny20-XU
Manufacturer:
Atmel
Quantity:
904
12.7.1
12.8
12.8.1
12.8.2
86
Modes of Operation
ATtiny20
Compare Output Mode and Waveform Generation
Normal Mode
Clear Timer on Compare Match (CTC) Mode
The design of the Output Compare pin logic allows initialization of the OC1x state before the out-
put is enabled. Note that some COM1x[1:0] bit settings are reserved for certain modes of
operation. See
The COM1x[1:0] bits have no effect on the Input Capture unit.
The Waveform Generator uses the COM1x[1:0] bits differently in normal, CTC, and PWM
modes. For all modes, setting the COM1x[1:0] = 0 tells the Waveform Generator that no action
on the OC1x Register is to be performed on the next compare match. For compare output
actions in the non-PWM modes refer to
Table 12-3 on page
Table 12-4 on page
A change of the COM1x[1:0] bits state will have effect at the first compare match after the bits
are written. For non-PWM modes, the action can be forced to have immediate effect by using
the FOC1x strobe bits.
The mode of operation, i.e., the behavior of the Timer/Counter and the Output Compare pins, is
defined by the combination of the Waveform Generation mode (WGM1[3:0]) and Compare Out-
put mode (COM1x[1:0]) bits. The Compare Output mode bits do not affect the counting
sequence, while the Waveform Generation mode bits do. The COM1x[1:0] bits control whether
the PWM output generated should be inverted or not (inverted or non-inverted PWM). For non-
PWM modes the COM1x[1:0] bits control whether the output should be set, cleared or toggle at
a compare match
For detailed timing information refer to
The simplest mode of operation is the Normal mode (WGM1[3:0] = 0). In this mode the counting
direction is always up (incrementing), and no counter clear is performed. The counter simply
overruns when it passes its maximum 16-bit value (MAX = 0xFFFF) and then restarts from the
BOTTOM (0x0000). In normal operation the Timer/Counter Overflow Flag (TOV1) will be set in
the same timer clock cycle as the TCNT1 becomes zero. The TOV1 flag in this case behaves
like a 17th bit, except that it is only set, not cleared. However, combined with the timer overflow
interrupt that automatically clears the TOV1 flag, the timer resolution can be increased by soft-
ware. There are no special cases to consider in the Normal mode, a new counter value can be
written anytime.
The Input Capture unit is easy to use in Normal mode. However, observe that the maximum
interval between the external events must not exceed the resolution of the counter. If the interval
between events are too long, the timer overflow interrupt or the prescaler must be used to
extend the resolution for the capture unit.
The Output Compare units can be used to generate interrupts at some given time. Using the
Output Compare to generate waveforms in Normal mode is not recommended, since this will
occupy too much of the CPU time.
In Clear Timer on Compare or CTC mode (WGM1[3:0] = 4 or 12), the OCR1A or ICR1 Register
are used to manipulate the counter resolution. In CTC mode the counter is cleared to zero when
“Register Description” on page 99
(“Compare Match Output Unit” on page
100.
99, and for phase correct and phase and frequency correct PWM refer to
“Timer/Counter Timing Diagrams” on page
Table 12-2 on page
85)
99. For fast PWM mode refer to
93.
8235B–AVR–04/11

Related parts for ATtiny20