DF2268FA13V Renesas Electronics America, DF2268FA13V Datasheet - Page 423

IC H8S/2268 MCU FLASH 100QFP

DF2268FA13V

Manufacturer Part Number
DF2268FA13V
Description
IC H8S/2268 MCU FLASH 100QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2200r
Datasheets

Specifications of DF2268FA13V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
13MHz
Connectivity
I²C, SCI, SmartCard
Peripherals
LCD, POR, PWM, WDT
Number Of I /o
67
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 10x10b, D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
100-QFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2268FA13V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
13.7.7
Data reception in Smart Card interface mode uses the same operation procedure as for normal
serial communication interface mode. Figure 13.32 illustrates the retransfer operation when the
SCI is in receive mode.
1. If an error is found when the received parity bit is checked, the PER bit in SSR is
2. The RDRF bit in SSR is not set for a frame in which an error has occurred.
3. If no error is found when the received parity bit is checked, the PER bit in SSR is not set to 1,
Figure 13.33 shows a flowchart for reception. In the H8S/2268 Group, a sequence of receive
operations can be performed automatically by specifying the DTC to be activated using an RXI
interrupt source. In a receive operation, an RXI interrupt request is generated when the RDRF flag
in SSR is set to 1. If the RXI request is designated beforehand as a DTC activation source, the
DTC will be activated by the RXI request, and the receive data will be transferred. The RDRF flag
is cleared to 0 automatically when the DISEL bit in DTC is 0 and the transfer counter is other than
0. When the DISEL bit in DTC is 1, or both the DISEL bit and the transfer counter are 0, flag is
not cleared although the receive data is transferred by DTC. Consequently, give the CPU an
instruction of flag clear processing. If an error occurs in receive mode and the ORER or PER flag
is set to 1, a transfer error interrupt (ERI) request will be generated. Hence, so the error flag must
be cleared to 0. In the event of an error, the DTC is not activated and receive data is skipped.
Therefore, receive data is transferred for only the specified number of bytes in the event of an
error. Even when a parity error occurs in receive mode and the PER flag is set to 1, the data that
has been received is transferred to RDR and can be read from there.
Note: For details on receive operations in block transfer mode, refer to section 13.4, Operation in
automatically set to 1. If the RIE bit in SCR is set at this time, an ERI interrupt request is
generated. The PER bit in SSR should be kept cleared to 0 until the next parity bit is sampled.
the receive operation is judged to have been completed normally, and the RDRF flag in SSR is
automatically set to 1. If the RIE bit in SCR is enabled at this time, an RXI interrupt request is
generated.
Asynchronous Mode.
Serial Data Reception (Except for Block Transfer Mode)
Section 13 Serial Communication Interface (SCI)
Rev. 5.00 Sep. 01, 2009 Page 371 of 656
REJ09B0071-0500

Related parts for DF2268FA13V