MCF5282CVF80J Freescale Semiconductor, MCF5282CVF80J Datasheet - Page 57

no-image

MCF5282CVF80J

Manufacturer Part Number
MCF5282CVF80J
Description
IC MPU 512K FLASH 256MAPBGA
Manufacturer
Freescale Semiconductor
Series
MCF528xr
Datasheet

Specifications of MCF5282CVF80J

Core Processor
Coldfire V2
Core Size
32-Bit
Speed
80MHz
Connectivity
CAN, EBI/EMI, Ethernet, I²C, SPI, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
150
Program Memory Size
512KB (512K x 8)
Program Memory Type
FLASH
Ram Size
64K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-40°C ~ 85°C
Package / Case
256-MAPBGA
Processor Series
MCF528x
Core
ColdFire V2
3rd Party Development Tools
JLINK-CF-BDM26, EWCF
Development Tools By Supplier
NNDK-MOD5282-KIT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCF5282CVF80J
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
instruction execution is performed in the second stage (EX) in one of the execute engines (e.g., ALU,
barrel shifter, divider, EMAC). There are no operand memory accesses associated with this class of
instructions, and the execution time is typically a single machine cycle. See
For memory-to-register (embedded-load) instructions, the instruction is effectively staged through the
OEP twice with a basic execution time of three cycles. First, the instruction is decoded and the components
of the operand address (base register from the RGF and displacement) are selected (DS). Second, the
operand effective address is generated using the ALU execute engine (AG). Third, the memory read
operand is fetched from the core bus, while any required register operand is simultaneously fetched (OC)
from the RGF. Finally, in the fourth cycle, the instruction is executed (EX). The heavily-used 32-bit load
instruction (
in
added to a base register Ay.
Freescale Semiconductor
Figure 2-12
Extension 1
Extension 2
Read Data
Core Bus
Opword
move.l <mem>y,Rx
shows an effective address of the form <ea>y = (d16,Ay), i.e., a 16-bit signed displacement
MCF5282 and MCF5216 ColdFire Microcontroller User’s Manual, Rev. 3
RGF
) is optimized to support a two-cycle execution time. The following example
Figure 2-11. V2 OEP Register-to-Register
Ry
DSOC
Operand Execution Pipeline
Rx
AGEX
new Rx
Figure
2-11.
Core Bus
Address
Core Bus
Write
Data
ColdFire Core
2-11