DSPIC33FJ128MC804-H/ML Microchip Technology, DSPIC33FJ128MC804-H/ML Datasheet - Page 389

16-bit DSC, 128KB Flash, Motor, CAN, DMA, 40 MIPS, NanoWatt 44 QFN 8x8x0.9mm TUB

DSPIC33FJ128MC804-H/ML

Manufacturer Part Number
DSPIC33FJ128MC804-H/ML
Description
16-bit DSC, 128KB Flash, Motor, CAN, DMA, 40 MIPS, NanoWatt 44 QFN 8x8x0.9mm TUB
Manufacturer
Microchip Technology
Series
dsPIC™ 33Fr
Datasheet

Specifications of DSPIC33FJ128MC804-H/ML

Core Processor
dsPIC
Core Size
16-Bit
Speed
20 MIPS
Connectivity
CAN, I²C, IrDA, LIN, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, DMA, Motor Control PWM, QEI, POR, PWM, WDT
Number Of I /o
35
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 9x10b/12b, D/A 6x16b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 140°C
Package / Case
44-QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
TABLE 31-46: ADC CONVERSION (12-BIT MODE) TIMING REQUIREMENTS
© 2011 Microchip Technology Inc.
AC CHARACTERISTICS
AD50
AD51
AD55
AD56
AD57
AD60
AD61
AD62
AD63
Note 1:
Param
dsPIC33FJ32MC302/304, dsPIC33FJ64MCX02/X04 AND dsPIC33FJ128MCX02/X04
No.
2:
3:
T
t
t
F
T
t
t
t
t
RC
CONV
PCS
PSS
CSS
DPU
Symbol
AD
SAMP
CNV
Because the sample caps will eventually lose charge, clock rates below 10 kHz may affect linearity
performance, especially at elevated temperatures.
These parameters are characterized but not tested in manufacturing.
The t
turned on (AD1CON1<ADON>=‘1’). During this time, the ADC result is indeterminate.
DPU
ADC Clock Period
ADC Internal RC Oscillator
Period
Conversion Time
Throughput Rate
Sample Time
Conversion Start from Sample
Trigger
Sample Start from Setting
Sample (SAMP) bit
Conversion Completion to
Sample Start (ASAM = 1)
Time to Stabilize Analog Stage
from ADC Off to ADC On
is the time required for the ADC module to stabilize at the appropriate level when the module is
(2)
Characteristic
(2)
(2)
(2)
Timing Parameters
Clock Parameters
Conversion Rate
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
3 T
117.6
2 T
2 T
Min.
AD
AD
AD
0.5 T
14 T
Typ
250
AD
AD
3 T
3 T
Max.
500
20
AD
AD
-40°C ≤ T
-40°C ≤ T
Units
Ksps
ns
ns
ns
μs
A
A
≤ +85°C for Industrial
≤ +125°C for Extended
Auto convert trigger not
selected
DS70291E-page 389
Conditions