I
The sequence repeats with successive targets until the CONT bit in the data structure is cleared and the
CRC check is executed. If the last register is not detected (that is, the CONT bit is never cleared) before
wrapping back to the first address, an error condition is detected, causing the device to hang and the
HRESET_REQ signal to assert externally. The I
as the continue (CONT) bit is set in the EEPROM(s). The CONT bit resides in the address/attributes field
that is transferred from the EEPROM, as described in
There should be no other I
The boot sequencer mode also supports an extension of the standard I
bits to allow for EEPROM devices that have more than 256 bytes, and this extended addressing mode is
selectable during POR with a different encoding on the cfg_boot_seq[0:1] reset configuration signals. In
this mode, only one EEPROM device may be used, and the maximum number of registers is limited by
the size of the EEPROM. If the boot sequencer is enabled for extended I
interface initiates the following sequence during reset:
Note that as described in
cfg_boot_seq[0:1] reset configuration pins is 0b11, which corresponds to the I
disabled at power-up.
11.4.5.1
The MPC8536E uses 0b101_0000 for the EEPROM calling address. The first EEPROM to be addressed
must be programmed to respond to this address, or an error is generated. If more EEPROMs are used, they
are addressed in sequential order.
11-18
2
C Interfaces
12. Transmit 0xA3 which is the 7-bit calling address (0b101_0001) with a read command appended (1
13. Receive another 256 bytes of data from the second EEPROM (unless the CONT bit is cleared in
1. Generate RESET sequence (START then 9 SCL cycles) to the EEPROM twice. This clears any
2. Generate START
3. Transmit 0xA0 which is the 7-bit calling address (0b101_0000) with a write command appended
4. Transmit 0x00 which is the high-order starting address
5. Transmit 0x00 which is the low-order starting address
6. Generate a repeated START
7. Transmit 0xA1 which is the 7-bit calling address (0b101_0000) with a read command appended (1
8. Receive data continuously from the EEPROM until the CONT bit is cleared and the CRC check is
as the least significant bit).
the data structure).
transactions that may have been in progress prior to the reset.
(0 as the least significant bit).
as the least significant bit).
executed. See
EEPROM Calling Address
MPC8536E PowerQUICC III Integrated Processor Reference Manual, Rev. 1
Section 11.4.5.2, “EEPROM Data
Section 4.4.3.11, “Boot Sequencer Configuration,”
2
C traffic when the boot sequencer is active.
2
C module continues to read from the EEPROM(s) as long
Section 11.4.5.1, “EEPROM Calling Address.”
Format,” for more information.
2
C interface that uses more address
2
C addressing mode, the I
the default value for the
2
C boot sequencer being
Freescale Semiconductor
2
C

Related parts for MPC8536E-ANDROID