UPD70F3737GF-GAS-AX Renesas Electronics America, UPD70F3737GF-GAS-AX Datasheet - Page 320

no-image

UPD70F3737GF-GAS-AX

Manufacturer Part Number
UPD70F3737GF-GAS-AX
Description
MCU 32BIT V850ES/JX3-L 100-LQFP
Manufacturer
Renesas Electronics America
Series
V850ES/Jx3-Lr
Datasheet

Specifications of UPD70F3737GF-GAS-AX

Core Processor
RISC
Core Size
32-Bit
Speed
20MHz
Connectivity
CSI, EBI/EMI, I²C, UART/USART
Peripherals
DMA, LVD, PWM, WDT
Number Of I /o
84
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
2.2 V ~ 3.6 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
UPD70F3737GF-GAS-AX
Manufacturer:
Renesas Electronics America
Quantity:
10 000
318
Figure 7-63. Example of Incorrect Processing When Capture Trigger Interval Is Long (When Using TIPn0)
(d) Processing of overflow if capture trigger interval is long
If the pulse width is greater than one cycle of the 16-bit counter, care must be exercised because an
overflow may occur more than once between the first capture trigger and the next. First, an example of
incorrect processing is shown below.
The following problem may occur when long pulse width is measured in the free-running timer mode.
<1> The TPnCCR0 register is read (the default value of the TIPn0 pin input is set).
<2> An overflow occurs. There is no software processing.
<3> An overflow occurs a second time. There is no software processing.
<4> The TPnCCR0 register is read.
If an overflow occurs twice or more when the capture trigger interval is long, the correct pulse width may
not be obtained.
If the capture trigger interval is long, slow the count clock to lengthen one cycle of the 16-bit counter, or
use software to resolve the problem. An example of how to use software to resolve the problem is shown
below.
TPnCCR0 register
INTTPnOV signal
The TPnOVF bit is read. The TPnOVF bit is 1, so it is cleared to 0.
Because the TPnOVF bit was 1, the pulse width can be calculated by (10000H + D
(incorrect).
Actually, the pulse width should be (20000H + D
TIPn0 pin input
16-bit counter
TPnOVF bit
TPnCE bit
FFFFH
0000H
CHAPTER 7 16-BIT TIMER/EVENT COUNTER P (TMP)
User’s Manual U18953EJ5V0UD
D
m0
<1> <2>
a1
− D
1 cycle of 16-bit counter
a0
) because an overflow occurred twice.
Pulse width
D
m0
<3> <4>
D
m1
D
m1
a1
− D
a0
)