HD64F3337YCP16 Renesas Electronics America, HD64F3337YCP16 Datasheet - Page 204

no-image

HD64F3337YCP16

Manufacturer Part Number
HD64F3337YCP16
Description
IC H8 MCU FLASH 60K 84PLCC
Manufacturer
Renesas Electronics America
Series
H8® H8/300r
Datasheets

Specifications of HD64F3337YCP16

Core Processor
H8/300
Core Size
8-Bit
Speed
16MHz
Connectivity
Host Interface, I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
74
Program Memory Size
60KB (60K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
84-PLCC
Package
84PLCC
Family Name
H8
Maximum Speed
16 MHz
Operating Supply Voltage
5 V
Data Bus Width
8 Bit
Number Of Programmable I/os
74
Interface Type
HIF/I2C/SCI
On-chip Adc
8-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
3
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3337YCP16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3337YCP16V
Manufacturer:
COILMASTER
Quantity:
30 000
Part Number:
HD64F3337YCP16V
Manufacturer:
RENESAS
Quantity:
1 029
Part Number:
HD64F3337YCP16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
8.3
The free-running counter (FRC), output compare registers (OCRA and OCRB), and input capture
registers (ICRA to ICRD) are 16-bit registers, but they are connected to an 8-bit data bus. When
the CPU accesses these registers, to ensure that both bytes are written or read simultaneously, the
access is performed using an 8-bit temporary register (TEMP).
These registers are written and read as follows:
Programs that access these registers should normally use word access. Equivalently, they may
access first the upper byte, then the lower byte by two consecutive byte accesses. Data will not be
transferred correctly if the bytes are accessed in reverse order, or if only one byte is accessed.
Figure 8.3 shows the data flow when FRC is accessed. The other registers are accessed in the same
way. As an exception, when the CPU reads OCRA or OCRB, it reads both the upper and lower
bytes directly, without using TEMP.
Coding Examples
172
To write the contents of general register R0 to OCRA:
To transfer the contents of ICRA to general register R0:
Register Write
When the CPU writes to the upper byte, the byte of write data is placed in TEMP. Next, when
the CPU writes to the lower byte, this byte of data is combined with the byte in TEMP and all
16 bits are written in the register simultaneously.
Register Read
When the CPU reads the upper byte, the upper byte of data is sent to the CPU and the lower
byte is placed in TEMP. When the CPU reads the lower byte, it receives the value in TEMP.
CPU Interface
MOV.W
MOV.W
R0, @OCRA
@ICRA, R0