HD64F3337YCP16 Renesas Electronics America, HD64F3337YCP16 Datasheet - Page 541

no-image

HD64F3337YCP16

Manufacturer Part Number
HD64F3337YCP16
Description
IC H8 MCU FLASH 60K 84PLCC
Manufacturer
Renesas Electronics America
Series
H8® H8/300r
Datasheets

Specifications of HD64F3337YCP16

Core Processor
H8/300
Core Size
8-Bit
Speed
16MHz
Connectivity
Host Interface, I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
74
Program Memory Size
60KB (60K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
84-PLCC
Package
84PLCC
Family Name
H8
Maximum Speed
16 MHz
Operating Supply Voltage
5 V
Data Bus Width
8 Bit
Number Of Programmable I/os
74
Interface Type
HIF/I2C/SCI
On-chip Adc
8-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
3
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3337YCP16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3337YCP16V
Manufacturer:
COILMASTER
Quantity:
30 000
Part Number:
HD64F3337YCP16V
Manufacturer:
RENESAS
Quantity:
1 029
Part Number:
HD64F3337YCP16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Bit 4—Flash Memory Control Register Enable (FLSHE): When the FLSHE bit is set to 1, the
flash memory control registers can be read and written to. When FLSHE is cleared to 0, the flash
memory control registers are unselected. In this case, the contents of the flash memory contents
are retained.
Bit 4: FLSHE
0
1
Bits 3 and 2—Wait Mode Select 1 and 0 (WMS1, WMS0)
Bits 1 and 0—Wait Count 1 and 0 (WC1, WC0)
These bits control insertion of wait states by the wait-state controller. For details, see section 5,
Wait-State Controller.
21.3
When an on-board programming mode is selected, the on-chip flash memory can be programmed,
erased, and verified. There are two on-board programming modes: boot mode and user
programming mode. Table 21.6 indicates how to select the on-board programming modes. User
programming mode operation can be performed by setting control bits with software. A state
transition diagram for flash memory related modes is shown in figure 21.2.
Table 21.6 On-Board Programming Mode Selection
Mode Selection
Boot mode
User programming
mode
21.3.1
To use boot mode, a user program for programming and erasing the flash memory must be
provided in advance on the host machine (which may be a personal computer). Serial
communication interface (SCI) channel 1 is used in asynchronous mode.
When a reset state is executed after the H8/3337SF pins have been set to boot mode, the built-in
boot program is activated, and the on-board update routine provided in the host is transferred
sequentially to the H8/3337SF using the serial communication interface (SCI). The H8/3337SF
writes the on-board update routine received via the SCI to the on-board update routine area in the
on-chip RAM. After the transfer is completed, execution branches to the first address of the on-
On-Board Programming Modes
Boot Mode
Description
Flash memory control registers are in unselected state
Flash memory control registers are in selected state
MD
0
1
1
MD
0
0
1
0
P9
1
2
P9
1
1
P9
1
(Initial value)
0
509