Notes
Port 0 Error and Status CSR
information.
Name:
This register is accessed when a local processor or an external device wishes to examine the port error and status
0
1
2
3
4
7:5
8
9
10
15:11
16
17
18
19
20
23:21
Bit
P0_ERR_STAT_CSR
PORT_UNINIT
PORT_OK
PORT_ERR
-
PORT_WR_PEND
-
IN_ERR_STOP
IN_ERR_ENC
IN_RTRY_STOP
-
OUT_ERR_STOP
OUT_ERR_ENC
OUT_RTRY_STOP
OUT_RETRY
OUT_RTRY_ENC
-
Field Name
1b1
1b0
1b0
0
1b0
0
1b0
1b0
1b0
0
1b0
1b0
1b0
1b0
1b0
0
Reset
Value
75 of 172
Address:
Table 33 Port 0 Error and Status CSR
Port Uninitialized:
Input and output ports are not initialized. This bit and bit 30 are mutu-
ally exclusive (read-only).
Port OK:
The input and output ports are initialized and the port is exchanging
error-free control symbols with the attached device (read-only).
Port Error:
Input or output port has encountered an error from which hardware
was unable to recover. Once set, remains set until written with a logic
1 to clear.
Reserved.
Port-write Pending:
Port has encountered a condition which required it to initiate a Main-
tenance Port-write operation. This bit is only valid if the device is
capable of issuing a maintenance port-write transaction. Once set,
remains set until written with a logic 1 to clear.
Reserved.
Input Error-stopped:
Input port is stopped due to transmission error (read-only).
Input Error-encountered:
Input port has encountered (and possibly recovered from) a trans-
mission error. This bit is set when bit 23 is set. Once set, remains set
until written with a logic 1 to clear.
Input Retry-stopped:
Input port is stopped due to a retry (read-only).
Reserved.
Output Error-stopped:
Output port is stopped due to a transmission error (read-only).
Output Error-encountered:
Output port has encountered (and possibly recovered from) a trans-
mission error. This bit is set when bit 15 is set. Once set, remains set
until written with a logic 1 to clear.
Output Retry-stopped:
Output port is stopped due to a retry (read-only).
Output Retried:
Output port has received a packet-retry control symbol and can not
make forward progress. This bit is set when bit 13 is set and cleared
when a packet-accepted or packet-not-accepted control symbol is
received (read-only).
Output Retry-encountered:
Output port has encountered a retry condition. This bit is set when bit
13 is set. Once set, remains set until written with a logic 1 to clear.
Reserved.