SDA5523 Micronas Semiconductor, SDA5523 Datasheet - Page 124

no-image

SDA5523

Manufacturer Part Number
SDA5523
Description
SDA55xx TVText Pro
Manufacturer
Micronas Semiconductor
Datasheet
SDA 55xx
Table 3–4: SFR register description, continued
124
Name
AVS
DVS
PWtmr
AHS
DHS
CISR1
CC
ADW
IEX1
IEX0
SNDCSTL
HYS
Sub
hC0[4]
hC0[3]
hC0[2]
hC0[1]
hC0[0]
hC8
hC8[7]
hC8[6]
hC8[1]
hC8[0]
hDF
hDF[6]
Dir
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
Reset
0
0
0
0
0
h00
0
0
0
0
Sept. 10, 2004; 6251-556-3DS
Range
0..1
0..1
0..1
0..1
0..1
0..1
0..1
0..1
0..1
Function
1: Acquisition vertical sync interrupt source bit set by hardware.
Source bit must be reset by software after servicing the interrupt.
0: Interrupt has not occurred.
1: Display Vertical sync interrupt source bit set by hardware.
Source bit must be reset by software after servicing the interrupt.
0: Interrupt has not occurred.
1: PWM in timer mode overflow interrupt source bit set by hardware.
Source bit must be reset by software after servicing the interrupt.
0: Interrupt has not occurred.
On reset this bit is initialized to 0,however if timer mode is selected
and timer is running, every over flow of timer will set this bit. Therefore
software must clear this bit before enabling the corresponding
interrupt.
1: Acquisition horizontal sync interrupt source bit set by hardware.
Source bit must be reset by software after servicing the interrupt.
0: Interrupt has not occurred.
1: Display horizontal sync interrupt source bit set by hardware.
Source bit must be reset by software after servicing the interrupt.
0: Interrupt has not occurred.
Central Interrupt Service 1
1: Channel change interrupt source bit set by hardware.
Source bit must be reset by software after servicing the interrupt.
0: Interrupt has not occurred.
1: ADC wake up interrupt source bit set by hardware.
Source bit must be reset by software after servicing the interrupt.
0: Interrupt has not occurred.
External Extra Interrupt 1 edge flag.
Set by hardware when external interrupt edge detected. Must be
cleared by software.
Port P3.7 must be in input mode to use this interrupt.
External Extra Interrupt 0 edge flag.
Set by hardware when external interrupt edge detected. Must be
cleared by software.
Port P3.1 must be in input mode to use this interrupt.
Sandcastle
Definition of Hysteresis (slave mode/sandcastle input)
Defines the voltage range for the Hysteresis:
0: Hysteresis set to 0.325 V.
1: Hysteresis set to 0.150 V.
DATA SHEET
Micronas

Related parts for SDA5523