Manufacturer Part Number
DS26519GA2
Description
Network Controller & Processor ICs
Manufacturer
Maxim Integrated
Datasheet

Specifications of DS26519GA2

Part # Aliases
90-26519-0A2
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Note: All bits in this register are real-time (not latched).
Bit 3: Receive Remote Alarm Indication Condition (RRAI). Set when a remote alarm is received at RRINGn and
RTIPn.
Bit 2: Receive Alarm Indication Signal Condition (RAIS). Set when an unframed all-ones code is received at
RRINGn and RTIPn.
Bit 1: Receive Loss of Signal Condition (RLOS). Set when 192 consecutive zeros have been detected at
RRINGn and RTIPn.
Bit 0: Receive Loss of Frame Condition (RLOF). Set when the DS26519 is not synchronized to the received
data stream.
7
0
RRTS1
Receive Real-Time Status Register 1
0B0h + (200h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16
6
0
5
0
207 of 310
4
0
RRAI
3
0
DS26519 16-Port T1/E1/J1 Transceiver
RAIS
2
0
RLOS
1
0
RLOF
0
0