DS26519GA2 Maxim Integrated, DS26519GA2 Datasheet - Page 253

no-image

DS26519GA2

Manufacturer Part Number
DS26519GA2
Description
Network Controller & Processor ICs
Manufacturer
Maxim Integrated
Datasheet

Specifications of DS26519GA2

Part # Aliases
90-26519-0A2
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 7: Manual Transmit AIS (TAIS). Alarm Indication Signal (AIS) is sent using MCLK as the reference clock. The
transmit data coming from the framer is ignored.
Bit : Automatic Transmit AIS (ATAIS)
Bits 5 to 3: Loopback Selection (LB[2:0]. See
Bit 2: Transmit Power-Down Enable (TPDE)
Bit 1: Receiver Power-Down Enable (RPDE)
Bit 0: Transmit Enable (TE). This function is overridden by the TXENABLE pin.
LB2
0
0
0
0
1
1
1
1
LB1
0 = TAIS is disabled.
1 = Output an unframed all-ones pattern (AIS) at TTIPn and TRINGn.
0 = ATAIS is disabled.
1 = Automatically transmit AIS on the occurrence of an LIU LOS.
0 = Transmitter power enabled.
1 = Transmitter powered down. TTIPn/TRINGn outputs are high impedance.
0 = Receiver power enabled.
1 = Receiver powered down.
0 = TTIPn/TRINGn outputs are high impedance.
1 = TTIPn/TRINGn outputs enabled.
0
0
1
1
0
0
1
1
TAIS
LB0
7
0
0
1
0
1
0
1
0
1
No loopback selected
Remote Loopback 2 (includes jitter attenuator)
Analog Loopback
Remote Loopback 1 (no jitter attenuator)
Local Loopback (includes jitter attenuator)
Dual Loopback—Remote Loopback 1 and Local Loopback (jitter
attenuator is included in Local Loopback)
Reserved
Reserved
LMCR
LIU Maintenance Control Register
1002h + (20h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16
ATAIS
6
0
LB2
5
0
Figure 9-27
Loopback Selection
253 of 310
LB1
4
0
for more details on each loopback.
LB0
3
0
DS26519 16-Port T1/E1/J1 Transceiver
TPDE
2
0
RPDE
1
0
TE
0
0

Related parts for DS26519GA2