DF2357F20 Renesas Electronics America, DF2357F20 Datasheet - Page 525

IC H8S MCU FLASH 5V 128K 128QFP

DF2357F20

Manufacturer Part Number
DF2357F20
Description
IC H8S MCU FLASH 5V 128K 128QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of DF2357F20

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
87
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
128-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2357F20
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
DF2357F20IV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Serial data reception (asynchronous mode)
Figure 14-7 shows a sample flowchart for serial reception.
The following procedure should be used for serial data reception.
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
Read RDRF flag in SSR
Clear RE bit in SCR to 0
Read ORER, PER, and
PER FER ORER= 1
FER flags in SSR
All data received?
Figure 14-7 Sample Serial Reception Data Flowchart
Start reception
Initialization
RDRF= 1
<End>
Yes
Yes
No
(Continued on next page)
Error processing
Yes
[1]
[2]
[4]
[5]
[3]
[1]
[2] [3]
[4]
[5]
SCI initialization:
The RxD pin is automatically
designated as the receive data
input pin.
break detection:
If a receive error occurs, read the
ORER, PER, and FER flags in
SSR to identify the error. After
performing the appropriate error
processing, ensure that the
ORER, PER, and FER flags are
all cleared to 0. Reception cannot
be resumed if any of these flags
are set to 1. In the case of a
framing error, a break can be
detected by reading the value of
the input port corresponding to
the RxD pin.
SCI status check and receive
data read :
Read SSR and check that RDRF
= 1, then read the receive data in
RDR and clear the RDRF flag to
0. Transition of the RDRF flag
from 0 to 1 can also be identified
by an RXI interrupt.
Serial reception continuation
procedure:
To continue serial reception,
before the stop bit for the current
frame is received, read the
RDRF flag, read RDR, and clear
the RDRF flag to 0. The RDRF
flag is cleared automatically
when the DMAC or DTC is
activated by an RXI interrupt and
the RDR value is read.
Receive error processing and
Rev.6.00 Oct.28.2004 page 495 of 1016
REJ09B0138-0600H

Related parts for DF2357F20