EM357-MOD-LR-ANT-TG Ember, EM357-MOD-LR-ANT-TG Datasheet - Page 131

MODULE EM357 PA/LNA W/ANT TG

EM357-MOD-LR-ANT-TG

Manufacturer Part Number
EM357-MOD-LR-ANT-TG
Description
MODULE EM357 PA/LNA W/ANT TG
Manufacturer
Ember
Datasheets

Specifications of EM357-MOD-LR-ANT-TG

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4 Zigbee
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
25mA
Current - Transmitting
42mA
Data Interface
PCB, Surface Mount
Memory Size
192kB Flash, 12kB RAM
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power - Output
-
Applications
-
Sensitivity
-
Other names
636-1020
When a UEV occurs, the update flag (the INT_TIMUIF bit in the INT_TIMxFLAG register) is set (unless TIM_USR
is 1) and the following registers are updated:
Figure 9-7 and Figure 9-8 show some examples of the counter behavior for different clock frequencies when
TIMx_ARR = 0x36.
9.3.2.3
In center-aligned mode, the counter counts from 0 to the auto-reload value (contents of the TIMx_ARR
register) – 1 and generates a counter overflow event, then counts from the autoreload value down to 1 and
generates a counter underflow event. Then it restarts counting from 0.
In this mode, the direction bit (TIM_DIR in the TIMx_CR1 register) cannot be written. It is updated by hardware
and gives the current direction of the counter.
The UEV can be generated at each counter overflow and at each counter underflow. Setting the TIM_UG bit in
the TIMx_EGR register by software or by using the slave mode controller also generates a UEV. In this case,
the both the counter and the prescaler’s counter restart counting from 0.
Software can disable the UEV by setting the TIM_UDIS bit in the TIMx_CR1 register. This avoids updating the
shadow registers while writing new values in the buffer registers. Then no UEV occurs until the TIM_UDIS bit
has been written to 0. However, the counter continues counting up and down, based on the current auto-
reload value.
The prescaler shadow register is reloaded with the buffer value (contents of the TIMx_PSC register).
The auto-reload active register is updated with the buffer value (contents of the TIMx_ARR register). The
auto-reload is updated before the counter is reloaded, so that the next period is the expected one.
Center-Aligned Mode (Up/Down Counting)
Figure 9-7. Counter Timing Diagram, Internal Clock Divided by 1
Figure 9-8. Counter Timing Diagram, Internal Clock Divided by 4
Final
9-7
120-035X-000G

Related parts for EM357-MOD-LR-ANT-TG