EM357-MOD-LR-ANT-TG Ember, EM357-MOD-LR-ANT-TG Datasheet - Page 135

MODULE EM357 PA/LNA W/ANT TG

EM357-MOD-LR-ANT-TG

Manufacturer Part Number
EM357-MOD-LR-ANT-TG
Description
MODULE EM357 PA/LNA W/ANT TG
Manufacturer
Ember
Datasheets

Specifications of EM357-MOD-LR-ANT-TG

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4 Zigbee
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
25mA
Current - Transmitting
42mA
Data Interface
PCB, Surface Mount
Memory Size
192kB Flash, 12kB RAM
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power - Output
-
Applications
-
Sensitivity
-
Other names
636-1020
Figure 9-15 gives an overview of the external trigger input block.
For example, to configure the up-counter to count each 2 rising edges on ETR, use the following procedure:
The counter counts once each 2 ETR rising edges. The delay between the rising edge on ETR and the actual
clock of the counter is due to the resynchronization circuit on the ETRP signal.
Figure 9-16 illustrates counting every 2 rising edges of ETR using external clock mode 2.
TIM_EXTRIGSEL bits Clock Signal Selection
As no filter is needed in this example, write TIM_ETF = 0000 in the TIMx_SMCR register.
Set the prescaler: Write TIM_ETPS = 01 in the TIMx_SMCR register.
Select rising edge detection on ETR: WriteTIM_ETP = 0 in the TIMx_SMCR register.
Enable external clock mode 2: Write TIM_ECE = 1 in the TIMx_SMCR register.
Enable the counter: Write TIM_CEN = 1 in the TIMx_CR1 register.
00
01
10
11
PCLK (peripheral clock). When running from the 24 MHz crystal oscillator, the PCLK
TIMxCLK pin. If the TIM_CLKMSKEN bit in the TIMx_OR register is set, this signal is
frequency is 12 MHz. When the 12 MHz RC oscillator is in use, the frequency is 6 MHz.
Calibrated 1 kHz internal RC oscillator
Optional 32.786 kHz clock
AND’ed with the TIMxMSK pin providing a gated clock input.
Table 9-2. TIM_EXTRIGSEL Clock Signal Selection
Figure 9-15. External Trigger Input Block
Final
9-11
EM351 / EM357
120-035X-000G