EM357-MOD-LR-ANT-TG Ember, EM357-MOD-LR-ANT-TG Datasheet - Page 147

MODULE EM357 PA/LNA W/ANT TG

EM357-MOD-LR-ANT-TG

Manufacturer Part Number
EM357-MOD-LR-ANT-TG
Description
MODULE EM357 PA/LNA W/ANT TG
Manufacturer
Ember
Datasheets

Specifications of EM357-MOD-LR-ANT-TG

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4 Zigbee
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
25mA
Current - Transmitting
42mA
Data Interface
PCB, Surface Mount
Memory Size
192kB Flash, 12kB RAM
Antenna Connector
On-Board, Chip
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Power - Output
-
Applications
-
Sensitivity
-
Other names
636-1020
The counter starts counting on the internal clock, then behaves normally until the TI1 rising edge. When TI1
rises, the counter is cleared and restarts from 0. In the meantime, the trigger flag is set (the INT_TIMTIF bit in
the INT_TIMxFLAG register) and an interrupt request can be sent if enabled (depending on the INT_TIMTIF bit
in the INT_TIMxCFG register).
Figure 9-27 shows this behavior when the auto-reload register TIMx_ARR = 0x36. The delay between the rising
edge on TI1 and the actual reset of the counter is due to the resynchronization circuit on the TI1 input.
9.3.13.2
In gated mode the counter is enabled depending on the level of a selected input.
In the following example, the up-counter counts only when the TI1 input is low:
The counter starts counting on the internal clock as long as TI1 is low and stops as soon as TI1 becomes high.
The INT_TIMTIF flag in the INT_TIMxFLAG register is set when the counter starts and when it stops. The delay
between the rising edge on TI1 and the actual stop of the counter is due to the resynchronization circuit on
the TI1 input.
Figure 9-28 shows the counter in gated mode with counting enabled when TI1 is low.
Configure channel 1 to detect low levels on TI1:
Configure the timer in gated mode: Write TIM_SMS = 101 in the TIMx_SMCR register.
Select TI1 as the input source by writing TIM_TS = 101 in the TIMx_SMCR register.
Enable the counter: Write TIM_CEN = 1 in the TIMx_CR1 register. In gated mode, the counter does not start
if TIM_CEN = 0, regardless of the trigger input level.
Slave Mode: Gated Mode
Configure the input filter duration. In this example, no filter is required, so TIM_IC1F = 0000.
The capture prescaler is not used for triggering, so it is not configured.
The TIM_CC1S bits select the input capture source only, TIM_CC1S = 01 in the TIMx_CCMR1 register.
Write TIM_CC1P = 1 in the TIMx_CCER register to validate the polarity (and detect low level only).
Figure 9-28. Control Circuit in Gated Mode
Figure 9-27. Control Circuit in Reset Mode
Final
9-23
120-035X-000G