EA-IF-E2

Manufacturer Part NumberEA-IF-E2
DescriptionINTERFACE ETHERNET (EA-PSI/BCI800R)
ManufacturerEA ELEKTRO-AUTOMATIK
EA-IF-E2 datasheet
 

Specifications of EA-IF-E2

SvhcNo SVHC (18-Jun-2010)Accessory TypeInterface Card
ApplicationsEngineering Laboratory And Complex Industrial ApplicationApproval BodiesCE / EN
Rohs CompliantYesFor Use WithEA Elektro-Automatik PSU
Lead Free Status / RoHS StatusLead free / RoHS Compliant  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
Page 71
72
Page 72
73
Page 73
74
Page 74
75
Page 75
76
Page 76
77
Page 77
78
Page 78
79
Page 79
80
Page 80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
Page 74/102

Download datasheet (2Mb)Embed
PrevNext
About the interface cards
4.5.9 Errors
Errors are collected in an error queue. The err bit indicates, if a new error has occured. It can be queried with a service
request call. The error queue is queried seperately and is automatically cleared when read.
<ERR> Message
0
“No error“
-100
“Command error“
-101
“Invalid character”
-10
“Syntax error“
-103
“Invalid separator“
-108
“Parameter not allowed”
-109
“Missing parameter“
-113
“Undefined header“
-10
“Numeric data error”
-131
“Invalid suffix”
-141
“Invalid character data“
-151
“Invalid string data“
-00
“Execution error“
-01-
“Invalid while in local”
-03
„Command protected“
-3
“Too much data“
-4
“Illegal parameter value”
-5
“Out of memory”
-40
“Hardware error”
-41
„Hardware missing”
-0
“Parameter error”
-1
“Settings conflict“
-
“Data out of range”
-3
“Too much data“
-3
“Invalid format“
-350
“Queue overflow”
-360
“Communication error”
-361
“Parity error in program message“
-36
“Framing error in program message“
-363
“Input buffer overrun“
-365
“Time out error“
Further error messages result from device depending alarms, warnings and notifications (see user manual of your device
for detailed information and the user manual of the interface card too, for the message):
<ERR>
Message
100 - 199
see alarm table in 9.4 of the
interface card user manual
00 - 99
see alarm table in 9.4 of the
interface card user manual
300 - 399
see alarm table in 9.4 of the
interface card user manual
© 009, Elektro-Automatik GmbH & Co. KG
Description
Error queue empty, no error present
Invalid command used
...in the command string
Command unknown
or unit
General error, used for various situations
Device is local, so remote mode is blocked
Access to sequence control denied or
Feature not enabled (R mode)
Access to functions parameters denied
max. CAN nodes exceeded / CAN node unknown/ no gateway
Object not defined
Read-write law violated, no access
Access to menu only when OUTPUT OFF
Access to set values denied (device is in slave mode)
Values exceeds upper or lower limit
Object length not correct
Time format wrong
Error and event buffer overflow
Various communication errors (also see 9..3):
Framing error
Checksum not correct
etc.
at RS3: Parity error
Description
displayed only, the ones and tens columns of the error code are identi-
cal to the error code in the table
warnings, the ones and tens columns of the error code are identical to
the error code in the table
alarms, the ones and tens columns of the error code are identical to the
error code in the table
EN