PEB2256E INFINEON [Infineon Technologies AG], PEB2256E Datasheet - Page 101

no-image

PEB2256E

Manufacturer Part Number
PEB2256E
Description
E1/T1/J1 Framer and Line Interface Component for Long and Short Haul Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet
4.4.7.4
In external signaling mode (serial mode) the signaling data received on port XSIG is
sampled with the working clock of the transmit system interface (SCLKX) in combination
with the transmit synchronization pulse (SYPX). Data on XSIG is latched in the bit
positions 5 to 8 per time slot, bits 1 to 4 are ignored. Time slots 0 and 16 are sampled
completely (bit 1 to 8). The received CAS multiframe is inserted frame aligned into the
data stream on XDI and must be valid during the last frame of a multiframe if CRC4/
multiframe mode is selected. The CAS multiframe is aligned to the CRC4-multiframe;
other frames are ignored. Data sourced by the internal signaling controller (µP access
mode) overwrites the external signaling data.
If the FALC56 is configured for no signaling, the system interface data stream passes
the FALC56 undisturbedly.
Note: CAS data on XSIG is read in the last frame of a multiframe only and ignored in all
Figure 26
4.4.7.5
Transmit data stored in registers XS(16:1) is transmitted on a multiframe boundary in
time slot 16. The signaling controller inserts the bit stream either on the transmit line side
or, if external signaling is enabled, on the transmit system side using pin function XSIG.
Data sourced by the internal signaling controller overwrites the external signaling data.
If the FALC56 is configured for no signaling, the system interface data stream passes
the FALC56 undisturbedly.
Data Sheet
SYPX
SCLKX
XDI
XSIG
other frames.
Channel Associated Signaling CAS (E1, serial mode)
Channel Associated Signaling CAS (E1, µP access mode)
T
FAS
NFAS
ABCD
0000XYXX
A B C D
4 5 6 7
2.048 MHz Transmit Signaling Highway (E1)
TS31
T
FAS/NFAS
FAS/NFAS
= Time slot offset (XC0, XC1)
= Frame alignment signal, is taken from XSIG, not from XDI
= TS0 not containing FAS
= Signaling bits for time slots 1...15 and 17...31 of CAS multiframe
= CAS multiframe alignment signal, has to be provided in TS16
TS0
0 1 2 3 4 5 6 7
TS1
A B C D
125 µs
101
0 1 2 3 4 5 6 7
0 0 0 0 X Y X X
TS16
Functional Description E1
0 1 2 3 4 5 6 7
FALC56 V1.2
TS31
A B C D
PEB 2256
2002-08-27
F0132