PEB2256E INFINEON [Infineon Technologies AG], PEB2256E Datasheet - Page 425

no-image

PEB2256E

Manufacturer Part Number
PEB2256E
Description
E1/T1/J1 Framer and Line Interface Component for Long and Short Haul Applications
Manufacturer
INFINEON [Infineon Technologies AG]
Datasheet
BOM
Receive Signaling Status Register (Read)
RSIS
RSIS relates to the last received HDLC or BOM frame; it is copied into RFIFO when end-
of-frame is recognized (last byte of each stored frame).
VFR
RDO
CRC16
Data Sheet
VFR
7
Bit Oriented Message - HDLC Channel 1
Significant only in ESF frame format and auto switching mode is
enabled.
0 =
1 =
Valid Frame - HDLC Channel 1
Determines whether a valid frame has been received.
1
0
An invalid frame is either
– a frame which is not an integer number of 8 bits (n 8 bits) in length
– a frame which is too short taking into account the operation mode
Note: Shorter frames are not reported.
Receive Data Overflow - HDLC Channel 1
A data overflow has occurred during reception of the frame.
Additionally, an interrupt can be generated
(refer to ISR1.RDO/IMR1.RDO).
CRC16 Compare/Check - HDLC Channel 1
0
1
RDO
(e.g. 25 bits), or
selected by MODE (MDS(2:0)) and the selection of receive CRC
on/off (CCR2.RCRC) as follows:
• MDS(2:0) = 011 (16 bit Address),
• MDS(2:0) = 010 (8 bit Address),
RCRC = 0: 4 bytes; RCRC = 1: 3 or 4 bytes
RCRC = 0: 3 bytes; RCRC = 1: 2 or 3 bytes
HDLC mode
BOM mode
CRC check failed; received frame contains errors.
CRC check o.k.; received frame is error-free.
Valid
Invalid
CRC16
RAB
425
HA1
HA0
HFR
T1/J1 Registers
FALC56 V1.2
LA
0
PEB 2256
2002-08-27
(65)