DF2398F20V Renesas Electronics America, DF2398F20V Datasheet - Page 527

IC H8S/2300 MCU FLASH 128QFP

DF2398F20V

Manufacturer Part Number
DF2398F20V
Description
IC H8S/2300 MCU FLASH 128QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheets

Specifications of DF2398F20V

Core Processor
H8S/2000
Core Size
16-Bit
Speed
20MHz
Connectivity
SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
87
Program Memory Size
256KB (256K x 8)
Program Memory Type
FLASH
Ram Size
8K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
128-QFP
For Use With
YR0K42378FC000BA - KIT EVAL FOR H8S/2378
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2398F20V
Manufacturer:
Renesas Electronics America
Quantity:
135
Part Number:
DF2398F20V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
In serial reception, the SCI operates as described below.
[1] The SCI monitors the transmission line, and if a 0 stop bit is detected, performs internal synchronization and starts
[2] The received data is stored in RSR in LSB-to-MSB order.
[3] The parity bit and stop bit are received.
Note: * Subsequent receive operations cannot be performed when a receive error has occurred.
[4] If the RIE bit in SCR is set to 1 when the RDRF flag changes to 1, a receive data full interrupt (RXI) request is
reception.
After receiving these bits, the SCI carries out the following checks.
[a] Parity check:
[b] Stop bit check:
[c] Status check:
If all the above checks are passed, the RDRF flag is set to 1, and the receive data is stored in RDR.
If a receive error* is detected in the error check, the operation is as shown in table 14-11.
generated.
Also, if the RIE bit in SCR is set to 1 when the ORER, PER, or FER flag changes to 1, a receive error interrupt (ERI)
request is generated.
The SCI checks whether the number of 1 bits in the receive data agrees with the parity (even or odd) set in the O/E
bit in SMR.
The SCI checks whether the stop bit is 1.
If there are two stop bits, only the first is checked.
The SCI checks whether the RDRF flag is 0, indicating that the receive data can be transferred from RSR to RDR.
Also note that the RDRF flag is not set to 1 in reception, and so the error flags must be cleared to 0.
Rev.6.00 Oct.28.2004 page 497 of 1016
REJ09B0138-0600H