HD64F2636UF20 Renesas Electronics America, HD64F2636UF20 Datasheet - Page 510

IC H8S MCU FLASH 128K 128QFP

HD64F2636UF20

Manufacturer Part Number
HD64F2636UF20
Description
IC H8S MCU FLASH 128K 128QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2636UF20

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI, SmartCard
Peripherals
Motor Control PWM, POR, PWM, WDT
Number Of I /o
72
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 12x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
128-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Section 13 Serial Communication Interface (SCI)
Bit 6—Receive Data Register Full (RDRF): Indicates that the received data is stored in RDR.
Bit 6
RDRF
0
1
Note: RDR and the RDRF flag are not affected and retain their previous values when an error is
Bit 5—Overrun Error (ORER): Indicates that an overrun error occurred during reception,
causing abnormal termination.
Bit 5
ORER
0
1
Notes: 1. The ORER flag is not affected and retains its previous state when the RE bit in SCR is
Page 460 of 1458
detected during reception or when the RE bit in SCR is cleared to 0.
If reception of the next data is completed while the RDRF flag is still set to 1, an overrun
error will occur and the receive data will be lost.
2. The receive data prior to the overrun error is retained in RDR, and the data received
cleared to 0.
subsequently is lost. Also, subsequent serial reception cannot be continued while the
ORER flag is set to 1. In clocked synchronous mode, serial transmission cannot be
continued, either.
Description
[Clearing conditions]
[Setting condition]
Description
[Clearing condition]
[Setting condition]
When 0 is written to RDRF after reading RDRF = 1
When the DTC is activated by an RXI interrupt and reads data from RDR
When serial reception ends normally and receive data is transferred from RSR to
RDR
When 0 is written to ORER after reading ORER = 1
When the next serial reception is completed while RDRF = 1 *
H8S/2639, H8S/2638, H8S/2636,
REJ09B0103-0800 Rev. 8.00
H8S/2630, H8S/2635 Group
2
(Initial value) *
(Initial value)
May 28, 2010
1