HD6412320 RENESAS [Renesas Technology Corp], HD6412320 Datasheet - Page 687

no-image

HD6412320

Manufacturer Part Number
HD6412320
Description
Renesas 16-Bit Single-Chip Microcomputer H8S Family H8S-2300 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412320VF25
Manufacturer:
HITACHI
Quantity:
1 045
Part Number:
HD6412320VF25IV
Manufacturer:
SEIKO
Quantity:
4 100
Part Number:
HD6412320VF25IV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412320VF25V
Manufacturer:
RENESAS
Quantity:
1 592
Part Number:
HD6412320VTE25
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6412320VTE25
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412320VTE25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Table 14.12 SCI Interrupt Sources
Channel
0
1
2
Notes: 1. This table shows the initial state immediate after a reset. Relative priorities among
A TEI interrupt is requested when the TEND flag is set to 1 while the TEIE bit is set to 1. The
TEND flag is cleared at the same time as the TDRE flag. Consequently, if a TEI interrupt and a
TXI interrupt are requested simultaneously, the TXI interrupt may be accepted first, with the result
that the TDRE and TEND flags are cleared. Note that the TEI interrupt will not be accepted in this
case.
2. The DMAC is not supported in the H8S/2321.
Interrupt
Source
ERI
RXI
TXI
TEI
ERI
RXI
TXI
TEI
ERI
RXI
TXI
TEI
channels can be changed by the interrupt controller.
Description
(ORER, FER, or PER)
state (RDRF)
state (TDRE)
(TEND)
(ORER, FER, or PER)
state (RDRF)
state (TDRE)
(TEND)
(ORER, FER, or PER)
state (RDRF)
state (TDRE)
(TEND)
Interrupt due to receive error
Interrupt due to receive data full
Interrupt due to transmit data empty
Interrupt due to transmission end
Interrupt due to receive error
Interrupt due to receive data full
Interrupt due to transmit data empty
Interrupt due to transmission end
Interrupt due to receive error
Interrupt due to receive data full
Interrupt due to transmit data empty
Interrupt due to transmission end
Section 14 Serial Communication Interface (SCI)
Rev.6.00 Sep. 27, 2007 Page 657 of 1268
DTC
Activation
Not
possible
Possible
Possible
Not
possible
Not
possible
Possible
Possible
Not
possible
Not
possible
Possible
Possible
Not
possible
DMAC *
Activation
Not
possible
Possible
Possible
Not
possible
Not
possible
Possible
Possible
Not
possible
Not
possible
Not
possible
Not
possible
Not
possible
REJ09B0220-0600
2
Priority *
High
Low
1

Related parts for HD6412320