HD6412320 RENESAS [Renesas Technology Corp], HD6412320 Datasheet - Page 936

no-image

HD6412320

Manufacturer Part Number
HD6412320
Description
Renesas 16-Bit Single-Chip Microcomputer H8S Family H8S-2300 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412320VF25
Manufacturer:
HITACHI
Quantity:
1 045
Part Number:
HD6412320VF25IV
Manufacturer:
SEIKO
Quantity:
4 100
Part Number:
HD6412320VF25IV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6412320VF25V
Manufacturer:
RENESAS
Quantity:
1 592
Part Number:
HD6412320VTE25
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD6412320VTE25
Manufacturer:
HITACHI/日立
Quantity:
20 000
Part Number:
HD6412320VTE25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 19 ROM
19.30
Precautions concerning the use of on-board programming mode, the RAM emulation function, and
PROM mode are summarized below.
Use the specified voltages and timing for programming and erasing: Applied voltages in
excess of the rating can permanently damage the device. Use a PROM programmer that supports
the Renesas microcomputer device type with 512-kbyte on-chip flash memory (FZTAT512V3A).
Do not select the HN27C4096 setting for the PROM programmer, and only use the specified
socket adapter. Failure to observe these points may result in damage to the device.
Powering on and off (see figures 19.86 to 19.88): Do not apply a high level to the FWE pin until
V
When applying or disconnecting V
the hardware protection state.
The power-on and power-off timing requirements should also be satisfied in the event of a power
failure and subsequent recovery.
FWE application/disconnection (see figures 19.86 to 19.88): FWE application should be carried
out when MCU operation is in a stable condition. If MCU operation is not stable, fix the FWE pin
low and set the protection state.
The following points must be observed concerning FWE application and disconnection to prevent
unintentional programming or erasing of flash memory:
• Apply FWE when the V
• Apply FWE when oscillation has stabilized (after the elapse of the oscillation stabilization
• In boot mode, apply and disconnect FWE during a reset.
• In user program mode, FWE can be switched between high and low level regardless of the
• Do not apply FWE if program runaway has occurred.
• Disconnect FWE only when the SWE1, ESU1, PSU1, EV1, PV1, P1, and E1 bits in FLMCR1,
Rev.6.00 Sep. 27, 2007 Page 906 of 1268
REJ09B0220-0600
CC
time).
reset state. FWE input can also be switched during execution of a program in flash memory.
and SWE2, ESU2, PSU2, EV2, PV2, P2, and E2 bits in FLMCR2 are cleared.
Make sure that the SWE1, ESU1, PSU1, EV1, PV1, P1, E1, and SWE2, ESU2, PSU2, EV2,
PV2, P2, and E2 bits are not set by mistake when applying or disconnecting FWE.
has stabilized. Also, drive the FWE pin low before turning off V
Flash Memory Programming and Erasing Precautions
CC
voltage has stabilized within its rated voltage range.
CC
power, fix the FWE pin low and place the flash memory in
CC
.