AT91SAM7X128-CU Atmel, AT91SAM7X128-CU Datasheet - Page 295

no-image

AT91SAM7X128-CU

Manufacturer Part Number
AT91SAM7X128-CU
Description
MCU ARM 128K HS FLASH 100-TFBGA
Manufacturer
Atmel
Series
AT91SAMr
Datasheet

Specifications of AT91SAM7X128-CU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
CAN, Ethernet, I²C, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
62
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TFBGA
For Use With
AT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9AT91SAM7X-EK - KIT EVAL FOR AT91SAM7X256/128
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7X128-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM7X128-CU-999
Manufacturer:
Atmel
Quantity:
10 000
29.6.1
Register Name:
Access Type:
• START: Send a START Condition
0 = No effect.
1 = A frame beginning with a START bit is transmitted according to the features defined in the mode register.
This action is necessary when the TWI peripheral wants to read data from a slave. When configured in Master Mode with a
write operation, a frame is sent as soon as the user writes a character in the Transmit Holding Register (TWI_THR).
• STOP: Send a STOP Condition
0 = No effect.
1 = STOP Condition is sent just after completing the current byte transmission in master read mode.
• MSEN: TWI Master Transfer Enabled
0 = No effect.
1 = If MSDIS = 0, the master data transfer is enabled.
• MSDIS: TWI Master Transfer Disabled
0 = No effect.
1 = The master data transfer is disabled, all pending data is transmitted. The shifter and holding characters (if they contain
data) are transmitted in case of write operation. In read operation, the character being transferred must be completely
received before disabling.
• SWRST: Software Reset
0 = No effect.
1 = Equivalent to a system reset.
6120H–ATARM–17-Feb-09
SWRST
– In single data byte master read, the START and STOP must both be set.
– In multiple data bytes master read, the STOP must be set after the last data received but one.
– In master read mode, if a NACK bit is received, the STOP is automatically performed.
– In multiple data write operation, when both THR and shift register are empty, a STOP condition is automatically
31
23
15
7
sent.
TWI Control Register
30
22
14
TWI_CR
Write-only
6
29
21
13
5
AT91SAM7X512/256/128 Preliminary
28
20
12
4
MSDIS
27
19
11
3
MSEN
26
18
10
2
STOP
25
17
9
1
START
24
16
8
0
295