AT91SAM7X128-CU Atmel, AT91SAM7X128-CU Datasheet - Page 556

no-image

AT91SAM7X128-CU

Manufacturer Part Number
AT91SAM7X128-CU
Description
MCU ARM 128K HS FLASH 100-TFBGA
Manufacturer
Atmel
Series
AT91SAMr
Datasheet

Specifications of AT91SAM7X128-CU

Core Processor
ARM7
Core Size
16/32-Bit
Speed
55MHz
Connectivity
CAN, Ethernet, I²C, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
62
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
100-TFBGA
For Use With
AT91SAM-ICE - EMULATOR FOR AT91 ARM7/ARM9AT91SAM7X-EK - KIT EVAL FOR AT91SAM7X256/128
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7X128-CU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7X128-CU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT91SAM7X128-CU-999
Manufacturer:
Atmel
Quantity:
10 000
36.8.16
Name:
Access Type:
These register fields are updated each time a message transfer is received or aborted.
MMI is cleared by reading the CAN_MSRx register.
MRDY, MABT are cleared by writing MTCR or MACR in the CAN_MCRx register.
Warning: MRTR and MDLC state depends partly on the mailbox object type.
• MTIMESTAMP: Timer value
This field is updated only when time-triggered operations are disabled (TTM cleared in CAN_MR register). If the TEOF field
in the CAN_MR register is cleared, TIMESTAMP is the internal timer value at the start of frame of the last message
received or sent by the mailbox. If the TEOF field in the CAN_MR register is set, TIMESTAMP is the internal timer value at
the end of frame of the last message received or sent by the mailbox.
In Time Triggered Mode, MTIMESTAMP is set to 0.
• MDLC: Mailbox Data Length Code
6120H–ATARM–17-Feb-09
MTIMESTAMP15 MTIMESTAMP14 MTIMESTAMP13 MTIMESTAMP12 MTIMESTAMP11 MTIMESTAMP10
MTIMESTAMP7
Mailbox Object Type
Receive
Receive with overwrite
Transmit
Consumer
Producer
MRDY
31
23
15
7
CAN Message Status Register
MTIMESTAMP6
MABT
30
22
14
Read-only
6
CAN_MSRx
MTIMESTAMP5
Description
Length of the first mailbox message received
Length of the last mailbox message received
No action
Length of the mailbox message received
Length of the mailbox message to be sent after the remote frame reception
29
21
13
5
MTIMESTAMP4
MRTR
AT91SAM7X512/256/128 Preliminary
28
20
12
4
MTIMESTAMP3
27
19
11
3
MTIMESTAMP2
26
18
10
2
MDLC
MTIMESTAMP9
MTIMESTAMP1
25
17
9
1
MTIMESTAMP8
MTIMESTAMP0
MMI
24
16
8
0
556