M29W640GB60ZA6E NUMONYX, M29W640GB60ZA6E Datasheet - Page 75

no-image

M29W640GB60ZA6E

Manufacturer Part Number
M29W640GB60ZA6E
Description
Flash Mem Parallel 3V/3.3V 64M-Bit 8M x 8/4M x 16 60ns 48-Pin TFBGA Tray
Manufacturer
NUMONYX
Datasheet

Specifications of M29W640GB60ZA6E

Package
48TFBGA
Cell Type
NOR
Density
64 Mb
Architecture
Sectored
Block Organization
Asymmetrical
Location Of Boot Block
Bottom
Typical Operating Supply Voltage
3|3.3 V
Sector Size
8KByte x 8|64KByte x 127
Timing Type
Asynchronous
Operating Temperature
-40 to 85 °C
Interface Type
Parallel
Appendix B
The common flash interface is a JEDEC approved, standardized data structure that can be
read from the Flash memory device. It allows a system software to query the device to
determine various electrical and timing parameters, density information and functions
supported by the memory. The system can interface easily with the device, enabling the
software to upgrade itself when necessary.
When the CFI Query command is issued the device enters CFI query mode and the data
structure is read from the memory. Tables 31, 32, 33, 34, 35, and 36, show the addresses
used to retrieve the data. The CFI data structure also contains a security area where a 64-
bit unique security number is written (see
accessed only in read mode by the final user. It is impossible to change the security number
after it has been written by Numonyx.
Table 31.
1. Query data are always presented on the lowest order data outputs.
Table 32.
1. Query data are always presented on the lowest order data outputs (DQ7-DQ0) only. DQ8-DQ15 are ‘0’.
x16
10h
12h
13h
14h
15h
16h
17h
18h
19h
1Ah
11h
1Bh
x16
10h
27h
40h
61h
Address
Address
2Ch 0000h
2Ah
2Eh
20h
22h
24h
26h
28h
30h
32h
34h
x8
4Eh
C2h
20h
36h
80h
x8
Common flash interface (CFI)
Query structure overview
CFI query identification string
0051h
0052h Query unique ASCII string ‘QRY’
0059h
0002h Primary algorithm command set and control interface ID code
0000h
0040h Address for primary algorithm extended query table (see
0000h Alternate vendor command set and control interface ID code
0000h
0000h
0000h
Data
CFI Query Identification String
System Interface Information
Device geometry definition
Primary algorithm-specific extended
query table
Security code area
16-bit ID code defining a specific algorithm
Table
second vendor - specified algorithm supported
Address for alternate algorithm extended query table
Sub-section name
35)
(1)
Table 36: Security code
Description
(1)
Command set ID and algorithm data offset
Device timing & voltage information
Flash device layout
Additional information specific to the
primary algorithm (optional)
64-bit unique device number
area). This area can be
Description
compatible
P = 40h
Value
AMD
NA
NA
‘Q’
‘R’
‘Y’
75/90

Related parts for M29W640GB60ZA6E