C8051T627-B-GM Silicon Labs, C8051T627-B-GM Datasheet - Page 51

no-image

C8051T627-B-GM

Manufacturer Part Number
C8051T627-B-GM
Description
8-bit Microcontrollers - MCU UBS, 64K OTP MCU
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051T627-B-GM

Rohs
yes
Core
8051
Processor Series
C8051T627
Data Bus Width
8 bit
Maximum Clock Frequency
48 MHz
Program Memory Size
64 KB
Data Ram Size
3328 B
On-chip Adc
Yes
Operating Supply Voltage
1.8 V to 5.25 V
Operating Temperature Range
- 40 C to + 85 C
Package / Case
QFN-32
Mounting Style
SMD/SMT
Program Memory Type
EPROM
SFR Definition 8.4. ADC0CN: ADC0 Control
SFR Address = 0xE8; Bit-Addressable
Name
Reset
Bit
2:0 AD0CM[2:0] ADC0 Start of Conversion Mode Select.
Type
7
6
5
4
3
Bit
AD0BUSY ADC0 Busy Bit.
AD0WINT
AD0INT
AD0EN
AD0TM
Name
AD0EN
R/W
7
0
ADC0 Enable Bit.
0: ADC0 Disabled. ADC0 is in low-power shutdown.
1: ADC0 Enabled. ADC0 is active and ready for data conversions.
ADC0 Track Mode Bit.
0: Normal Track Mode: When ADC0 is enabled, tracking is continuous unless a con-
version is in progress. Conversion begins immediately on start-of-conversion event,
as defined by AD0CM[2:0].
1: Delayed Track Mode: When ADC0 is enabled, input is tracked when a conversion
is not in progress. A start-of-conversion signal initiates three SAR clocks of additional
tracking, and then begins the conversion.
ADC0 Conversion Complete Interrupt Flag.
0: ADC0 has not completed a data conversion since AD0INT was last cleared.
1: ADC0 has completed a data conversion.
ADC0 Window Compare Interrupt Flag.
0: ADC0 Window Comparison Data match has not occurred since this flag was last
cleared.
1: ADC0 Window Comparison Data match has occurred.
000: ADC0 start-of-conversion source is write of 1 to AD0BUSY.
001: ADC0 start-of-conversion source is overflow of Timer 0.
010: ADC0 start-of-conversion source is overflow of Timer 2.
011: ADC0 start-of-conversion source is overflow of Timer 1.
100: ADC0 start-of-conversion source is rising edge of external CNVSTR.
101: ADC0 start-of-conversion source is overflow of Timer 3.
11x: Reserved.
AD0TM
R/W
6
0
C8051T620/1/6/7 & C8051T320/1/2/3
AD0INT
R/W
5
0
Read:
0: ADC0 conversion is not in
progress.
1: ADC0 conversion is in prog-
ress.
AD0BUSY AD0WINT
R/W
Rev. 1.2
4
0
Function
R/W
3
0
Write:
0: No Effect.
1: Initiates ADC0 Conversion if
AD0CM[2:0] = 000b
2
0
AD0CM[2:0]
R/W
1
0
0
0
51