Core Size
16-Bit
Program Memory Size
32KB (32K x 8)
Oscillator Type
External
Core Processor
H8/300H
Speed
16MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
29
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Operating Temperature
-20°C ~ 75°C
Package / Case
64-LQFP
No. Of I/o's
29
Ram Memory Size
2KB
Cpu Speed
16MHz
No. Of Timers
4
Digital Ic Case Style
LQFP
Supply Voltage
RoHS Compliant
Controller Family/series
H8/300H
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3664FPV
Manufacturer:
MURATA
Quantity:
34 000
Part Number:
HD64F3664FPV
Manufacturer:
HD
Quantity:
465
Part Number:
HD64F3664FPV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3664FPV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664FPV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664FPV
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664FPV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F3664FPV
0
Timer A is an 8-bit timer with interval timing and real-time clock time-base functions. The clock
time-base function is available when a 32.768kHz crystal oscillator is connected. Figure 10.1
shows a block diagram of timer A.
10.1
• Timer A can be used as an interval timer or a clock time base.
• An interrupt is requested when the counter overflows.
• Any of eight clock signals can be output from pin TMOW: 32.768 kHz divided by 32, 16, 8, or
Interval Timer:
• Choice of eight internal clock sources (φ/8192, φ/4096, φ/2048, φ/512, φ/256, φ/128, φ/32, φ8)
Clock Time Base:
• Choice of four overflow periods (1 s, 0.5 s, 0.25 s, 31.25 ms) when timer A is used as a clock
4 (1 kHz, 2 kHz, 4 kHz, 8 kHz), or the system clock divided by 32, 16, 8, or 4.
time base (using a 32.768 kHz crystal oscillator).
Features
Section 10 Timer A
Rev. 6.00 Mar. 24, 2006 Page 139 of 412
Section 10 Timer A
REJ09B0142-0600