DS33Z41 Maxim Integrated Products, DS33Z41 Datasheet - Page 74

no-image

DS33Z41

Manufacturer Part Number
DS33Z41
Description
Network Controller & Processor ICs Quad Inverse-Multipl exing Ethernet Mappe
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of DS33Z41

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DS33Z41
Manufacturer:
Maxim Integrated
Quantity:
10 000
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bit 6: T1E1 Mode (T1E1). This bit determines if IMUX if for T1 or E1 Mode.
Bit 5: Receive Enable (RXE). If this bit is set to 1, data will be received from the Serial Interface and passed to
the packet processor. If equal to 0, no data will be sent to the packet processor.
Bit 4: SEND Enable (SENDE). If this bit is set to 1, the data will be transmitted on the Serial Interface. If equal to
0, data is blocked.
Bit 3: Link 4 (L4). If this bit is set to 1, link number four is participating in the communication. If this bit is equal to
0, the link does not participate.
Bit 2: Link 3 (L3). If this bit is set to 1, link number three is participating in the communication. If this bit is equal
to 0, the link does not participate.
Bit 1: Link 2 (L2). If this bit is set to 1, link number two is participating in the communication. If this bit is equal to
0, the link does not participate.
Bit 0: Link 1 (L1). If this bit is set to 1, link number one is participating in the communication. If this bit is equal to
0, the link does not participate.
Register Name:
Register Description:
Register Address:
Bit #
Name
Default
Bits 0 to 7: Inverse Multiplexing Command (IMUXC[0:7]). This byte is used to issue IMUX commands.
AVAILABLE USER COMMANDS
The user must send a link start command. The NOP command may be written to this register after the link start
command is written. All values other than those listed above will be ignored.
1111 1111b
1000 0010b
VALUE
0 = T1 Mode
1 = E1 Mode
IMUXC7
7
0
7
1
COMMAND
Link Start
IMUXC6
NOP
T1E1
6
0
6
1
GL.IMXCN
Inverse MUX Configuration Register
16h
GL.IMXC
Inverse MUX Command Register
17h
IMUXC5
No operation to perform.
Establish Link with the distant end. Upon reception of this message,
this distant end begins searching for 3 consecutive sequence
numbers.
RXE
5
0
5
1
IMUXC4
SENDE
74 of 167
4
0
4
1
IMUXC3
L4
3
0
3
1
COMMENT
IMUXC2
L3
2
0
2
1
IMUXC1
L2
1
0
1
1
IMUXC0
L1
0
0
0
1

Related parts for DS33Z41