AT32UC3B1128-AUT Atmel, AT32UC3B1128-AUT Datasheet - Page 357

IC MCU AVR32 128KB FLASH 48-TQFP

AT32UC3B1128-AUT

Manufacturer Part Number
AT32UC3B1128-AUT
Description
IC MCU AVR32 128KB FLASH 48-TQFP
Manufacturer
Atmel
Series
AVR®32 UC3r
Datasheets

Specifications of AT32UC3B1128-AUT

Core Processor
AVR
Core Size
32-Bit
Speed
60MHz
Connectivity
I²C, IrDA, SPI, SSC, UART/USART, USB
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Number Of I /o
28
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
32K x 8
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Data Converters
A/D 6x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
48-TQFP, 48-VQFP
Package
48TQFP
Device Core
AVR32
Family Name
AT32
Maximum Speed
60 MHz
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Number Of Programmable I/os
28
Interface Type
I2S/SPI/TWI/USART/USB
On-chip Adc
6-chx10-bit
Number Of Timers
3
For Use With
ATSTK600-TQFP48 - STK600 SOCKET/ADAPTER 48-TQFPATAVRONEKIT - KIT AVR/AVR32 DEBUGGER/PROGRMMR770-1008 - ISP 4PORT ATMEL AVR32 MCU SPIATEVK1101 - KIT DEV/EVAL FOR AVR32 AT32UC3B
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT32UC3B1128-AUT
Manufacturer:
Atmel
Quantity:
10 000
21.7.15
Name:
Access Type:
Offset:
Reset Value:
This register can only be written if the WPEN bit is cleared in the Write Protect Mode Register (if exists).
Table 21-22.
32059K–03/2011
DRIFT: Drift compensation
RX_MPOL: Receiver Manchester Polarity
RX_PP: Receiver Preamble Pattern detected
RX_PL: Receiver Preamble Length
TX_MPOL: Transmitter Manchester Polarity
31
23
15
7
0
0
1
1
0: The USART can not recover from an important clock drift
1: The USART can recover from clock drift. The 16X clock mode must be enabled.
0: Logic Zero is coded as a zero-to-one transition, Logic One is coded as a one-to-zero transition.
1: Logic Zero is coded as a one-to-zero transition, Logic One is coded as a zero-to-one transition.
0: The receiver preamble pattern detection is disabled
1 - 15: The detected preamble length is RX_PL x Bit Period
0: Logic Zero is coded as a zero-to-one transition, Logic One is coded as a one-to-zero transition.
1: Logic Zero is coded as a one-to-zero transition, Logic One is coded as a zero-to-one transition.
Manchester Configuration Register
RX_PP
DRIFT
30
22
14
MAN
Read-write
0x50
0x30011004
6
0
1
0
1
Preamble Pattern default polarity assumed (RX_MPOL field not set)
ALL_ONE
ALL_ZERO
ZERO_ONE
ONE_ZERO
29
21
13
1
5
RX_MPOL
TX_MPOL
28
20
12
4
27
19
11
3
26
18
10
2
RX_PL
TX_PL
25
17
9
1
AT32UC3B
RX_PP
TX_PP
24
16
8
0
357