HD64F3664H Renesas Electronics America, HD64F3664H Datasheet - Page 252

IC H8 MCU FLASH 32K 64QFP

HD64F3664H

Manufacturer Part Number
HD64F3664H
Description
IC H8 MCU FLASH 32K 64QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3664H

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
29
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
64-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3664H
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F3664H
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F3664H H8/3664
Manufacturer:
RENESAS
Quantity:
13
Part Number:
HD64F3664HJ
Manufacturer:
TI
Quantity:
171
Part Number:
HD64F3664HJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664HJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F3664HV
Manufacturer:
ALTERA
Quantity:
101
Part Number:
HD64F3664HV
Manufacturer:
RENESAS
Quantity:
630
Part Number:
HD64F3664HV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3664HV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 14 Serial Communication Interface 3 (SCI3)
Reception cannot be resumed while a receive error flag is set to 1. Accordingly, clear the OER,
FER, PER, and RDRF bits to 0 before resuming reception. Figure 14.13 shows a sample flowchart
for serial data reception.
Rev. 6.00 Mar. 24, 2006 Page 222 of 412
REJ09B0142-0600
Figure 14.13 Sample Serial Reception Flowchart (Clocked Synchronous Mode)
[4]
Yes
No
Clear OER flag in SSR to 0
Read receive data in RDR
Clear RE bit in SCR3 to 0
Overrun error processing
Read RDRF flag in SSR
Read OER flag in SSR
All data received?
Error processing
Start reception
RDRF = 1
OER = 1
<End>
<End>
Yes
No
No
(Continued below)
Error processing
Yes
[1]
[2]
[3]
[4]
[1] Read the OER flag in SSR to determine
[2] Read SSR and check that the RDRF
[3] To continue serial reception, before the
[4] If an overrun error occurs, read the
if there is an error. If an overrun error
has occurred, execute overrun error
processing.
flag is set to 1, then read the receive
data in RDR. When data is read from
RDR, the RDRF flag is automatically
cleared to 0.
MSB (bit 7) of the current frame is
received, reading the RDRF flag and
reading RDR should be finished. When
data is read from RDR, the RDRF flag
is automatically cleared to 0.
OER flag in SSR, and after performing
the appropriate error processing, clear
the OER flag to 0. Reception cannot be

Related parts for HD64F3664H