HD64F3664H Renesas Electronics America, HD64F3664H Datasheet - Page 273

IC H8 MCU FLASH 32K 64QFP

HD64F3664H

Manufacturer Part Number
HD64F3664H
Description
IC H8 MCU FLASH 32K 64QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3664H

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
29
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
64-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3664H
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F3664H
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F3664H H8/3664
Manufacturer:
RENESAS
Quantity:
13
Part Number:
HD64F3664HJ
Manufacturer:
TI
Quantity:
171
Part Number:
HD64F3664HJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664HJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F3664HV
Manufacturer:
ALTERA
Quantity:
101
Part Number:
HD64F3664HV
Manufacturer:
RENESAS
Quantity:
630
Part Number:
HD64F3664HV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3664HV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Bit
3
2
Bit Name
ACKE
BBSY
Initial
Value
0
0
R/W
R/W
R/W
Description
Acknowledge Bit Judgement Selection
0: The value of the acknowledge bit is ignored, and
1: If the acknowledge bit is 1, continuous transfer is
Bus Busy
In slave mode, reading the BBSY flag enables to
confirm whether the I
The BBSY flag is set to 0 when the SDA level changes
from high to low under the condition of SCl = high,
assuming that the start condition has been issued. The
BBSY flag is cleared to 0 when the SDA level changes
from low to high under the condition of SCl = high,
assuming that the start condition has been issued.
Writing to the BBSY flag in slave mode is disabled.
In master mode, the BBSY flag is used to issue start
and stop conditions. Write 1 to BBSY and 0 to SCP to
issue a start condition. Follow this procedure when also
re-transmitting a start condition. To issue a start/stop
condition, use the MOV instruction. The I
interface must be set in master transmit mode before
the issue of a start condition.
continuous transfer is performed. The value of the
received acknowledge bit is not indicated by the
ACKB bit, which is always 0.
interrupted.
Rev. 6.00 Mar. 24, 2006 Page 243 of 412
2
C bus is occupied or released.
Section 15 I
2
C Bus Interface (IIC)
REJ09B0142-0600
2
C bus

Related parts for HD64F3664H