HD64F3664H Renesas Electronics America, HD64F3664H Datasheet - Page 308

IC H8 MCU FLASH 32K 64QFP

HD64F3664H

Manufacturer Part Number
HD64F3664H
Description
IC H8 MCU FLASH 32K 64QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3664H

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
I²C, SCI
Peripherals
PWM, WDT
Number Of I /o
29
Program Memory Size
32KB (32K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
External
Operating Temperature
-20°C ~ 75°C
Package / Case
64-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3664H
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F3664H
Manufacturer:
HIT
Quantity:
1 000
Part Number:
HD64F3664H H8/3664
Manufacturer:
RENESAS
Quantity:
13
Part Number:
HD64F3664HJ
Manufacturer:
TI
Quantity:
171
Part Number:
HD64F3664HJ
Manufacturer:
RENESAS
Quantity:
1 000
Part Number:
HD64F3664HJ
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F3664HV
Manufacturer:
ALTERA
Quantity:
101
Part Number:
HD64F3664HV
Manufacturer:
RENESAS
Quantity:
630
Part Number:
HD64F3664HV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3664HV
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Section 16 A/D Converter
16.3
The A/D converter has the following registers.
• A/D data register A (ADDRA)
• A/D data register B (ADDRB)
• A/D data register C (ADDRC)
• A/D data register D (ADDRD)
• A/D control/status register (ADCSR)
• A/D control register (ADCR)
16.3.1
There are four 16-bit read-only ADDR registers; ADDRA to ADDRD, used to store the results of
A/D conversion. The ADDR registers, which store a conversion result for each channel, are
shown in table 16.2.
The converted 10-bit data is stored in bits 6 to 15. The lower 6 bits are always read as 0.
The data bus between the CPU and the A/D converter is 8 bits wide. The upper byte can be read
directly from the CPU, however the lower byte should be read via a temporary register. The
temporary register contents are transferred from the ADDR when the upper byte data is read.
Therefore, byte access to ADDR should be done by reading the upper byte first then the lower
one. Word access is also possible. ADDR is initialized to H'0000.
Table 16.2 Analog Input Channels and Corresponding ADDR Registers
Rev. 6.00 Mar. 24, 2006 Page 278 of 412
REJ09B0142-0600
Group 0
AN0
AN1
AN2
AN3
Analog Input Channel
Register Description
A/D Data Registers A to D (ADDRA to ADDRD)
Group 1
AN4
AN5
AN6
AN7
A/D Data Register to be Stored Results of A/D Conversion
ADDRA
ADDRB
ADDRC
ADDRD

Related parts for HD64F3664H