5M1270ZT144C4N Altera, 5M1270ZT144C4N Datasheet - Page 116

no-image

5M1270ZT144C4N

Manufacturer Part Number
5M1270ZT144C4N
Description
ALTERA
Manufacturer
Altera
Series
MAX® Vr
Datasheets

Specifications of 5M1270ZT144C4N

Programmable Type
In System Programmable
Delay Time Tpd(1) Max
6.2ns
Voltage Supply - Internal
1.71 V ~ 1.89 V
Number Of Logic Elements/blocks
1270
Number Of Macrocells
980
Number Of Gates
-
Number Of I /o
114
Operating Temperature
0°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
144-LQFP
Lead Free Status / Rohs Status
Vendor undefined / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5M1270ZT144C4N
Manufacturer:
ALTERA
Quantity:
200
Part Number:
5M1270ZT144C4N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
5M1270ZT144C4N
Manufacturer:
ALTERA
0
Part Number:
5M1270ZT144C4N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
7–14
Table 7–5. ALTUFM_I2C Interface Signals
Figure 7–9. Start and Stop Conditions
MAX V Device Handbook
SDA
SCL
WP
A
2
, A
Pin
1
, A
0
SDA
SCL
Serial Data/Address Line
Serial Clock Line
Write Protect
Slave Address Input
Start Condition
Description
Table 7–5
START and STOP Condition
The master always generates start (S) and stop (P) conditions. After the start
condition, the bus is considered busy. Only a stop (P) condition frees the bus. The bus
stays busy if the repeated start (Sr) condition is executed instead of a stop condition.
In this occurrence, the start (S) and repeated start (Sr) conditions are functionally
identical.
A high-to-low transition on the SDA line while the SCL is high indicates a start
condition. A low-to-high transition on the SDA line while the SCL is high indicates a
stop condition.
S
Data transfer can be initiated only when the bus is free.
The data on the SDA line must be stable during the high period of the clock. The
high or low state of the data line can only change when the clock signal on the SCL
line is low.
Any transition on the SDA line while the SCL is high indicates a start or stop
condition.
lists the ALTUFM_I2C megafunction input and output interface signals.
Figure 7–9
The bidirectional SDA port is used to transmit and receive serial data from the
UFM. The output stage of the SDA port is configured as an open drain pin to
perform the wired-AND function.
The bidirectional SCL port is used to synchronize the serial data transfer to and
from the UFM. The output stage of the SCL port is configured as an open drain
pin to perform a wired-AND function.
Optional active high signal that disables the erase and write function for
read/write mode. The ALTUFM_I2C megafunction gives you an option to
protect the entire UFM memory or only the upper half of memory.
These inputs set the UFM slave address. The A
are programmable, set internally to 1010 by default.
shows the start and stop conditions.
Function
Chapter 7: User Flash Memory in MAX V Devices
Stop Condition
6
, A
5
January 2011 Altera Corporation
P
, A
Software Support for UFM Block
4
, A
3
slave address bits
SDA
SCL