HD6417706F133 Renesas Electronics America, HD6417706F133 Datasheet - Page 486

IC SUPERH MPU ROMLESS 176LQFP

HD6417706F133

Manufacturer Part Number
HD6417706F133
Description
IC SUPERH MPU ROMLESS 176LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417706F133

Core Processor
SH-3
Core Size
32-Bit
Speed
133MHz
Connectivity
EBI/EMI, FIFO, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
103
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.75 V ~ 2.05 V
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
176-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417706F133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
Section 15 Smart Card Interface
1. Initialize the smart card interface mode as described above in Initialization and in figure 15.5.
2. Check that the ORER and PER flags in SCSSR are cleared to 0. If either flag is set, clear both
3. Repeat steps 2 and 3 until the RDRF flag is set to 1.
4. Read the receive data from SCRDR.
5. To receive more data, clear the RDRF flag to 0 and return to step 2.
6. To end reception, clear the RE bit to 0.
This processing can be interrupted. When the RIE bit is set to 1 and interrupt requests are enabled,
a receive-data-full interrupt (RXI) will be requested when the RDRF flag is set to 1 at the end of
the reception. When an error occurs during reception and either the ORER or PER flag is set to 1,
a communication error interrupt (ERI) will be requested. See Interrupt Operation below for more
information.
The received data will be transferred to SCRDR even when a parity error occurs during reception
and PER is set to 1, so this data can still be read.
Rev. 5.00 May 29, 2006 page 436 of 698
REJ09B0146-0500
to 0 after performing the appropriate error processing procedures.
Figure 15.7 Reception Flowchart (Example)
No
No
Clear RE bit in SCSCR to 0
RDRF flag in SCSSR to 0
ORER = 0 or PER = 0?
Write receive data from
All data received?
SCRDR and clear
Start reception
End reception
RDRF = 1?
Initialize
Start
Yes
Yes
Yes
No
Error processing

Related parts for HD6417706F133