HD6417706F133 Renesas Electronics America, HD6417706F133 Datasheet - Page 526

IC SUPERH MPU ROMLESS 176LQFP

HD6417706F133

Manufacturer Part Number
HD6417706F133
Description
IC SUPERH MPU ROMLESS 176LQFP
Manufacturer
Renesas Electronics America
Series
SuperH® SH7700r
Datasheet

Specifications of HD6417706F133

Core Processor
SH-3
Core Size
32-Bit
Speed
133MHz
Connectivity
EBI/EMI, FIFO, SCI, SmartCard
Peripherals
DMA, POR, WDT
Number Of I /o
103
Program Memory Type
ROMless
Ram Size
16K x 8
Voltage - Supply (vcc/vdd)
1.75 V ~ 2.05 V
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
176-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-
Program Memory Size
-
Data Converters
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6417706F133
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD6417706F133V
Manufacturer:
EDISON
Quantity:
2 000
Part Number:
HD6417706F133V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD6417706F133V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Company:
Part Number:
HD6417706F133V
Quantity:
27
Section 16 Serial Communication Interface with FIFO (SCIF)
Serial data reception: Figure 16.9 shows a sample flowchart for serial reception.
Use the following procedure for serial data reception after enabling the SCIF for reception.
Rev. 5.00 May 29, 2006 page 476 of 698
REJ09B0146-0500
No
No
Read receive data in SCFRDR2,
Clear RE bit in SCSCR2 to 0
Read RDF flag in SCSSR2
Read ORER, PER, FER
and clear RDF flag in
PER = 1 or FER = 1?
All data received?
Figure 16.9 Sample Serial Reception Flowchart (1)
flags in SCSSR2
Start reception
End reception
SCSSR2 to 0
RDF = 1?
No
Yes
Yes
Error processing
Yes
1. Receive error handling and break detection:
2. SCIF status check and receive data read :
3. Serial reception continuation procedure: To
Read the DR, ER, and BRK flags in SCSSR2
to identify any error, perform the appropriate
error handling, then clear the DR, ER, and
BRK flags to 0. In the case of a framing
error, a break can also be detected by
reading the value of the RxD2 pin.
Read the SCSSR2 and check that RDF = 1,
then read the receive data in SCFRDR2, read
1 from the RDF flag, and then clear the RDF
flag to 0. The transition of the RDF flag from
0 to 1 can be identified by an RXI interrupt.
continue serial reception, read at least the
receive trigger set number of receive data
bytes from SCFRDR2, read 1 from the RDF
flag, then clear the RDF flag to 0. The
number of receive data bytes in SCFRDR2
can be ascertained by reading the lower bits
of SCFDR2.

Related parts for HD6417706F133