Operation
3-6
3-6-1 Setting PTP Data (When UP-01 is 11 or 12)
Use the following procedure to set the PTP data (Pd01
3-34
1. Press the Mode Key to go to the PTP Data Edit Mode (Pd01H).
2. Use the Increment and Decrement Keys to display the parameter number (Pd
3. Press the Increment Key to display the parameter data.
4. Press the Data Key and Shift Key simultaneously to enable a data change. The rightmost digit will
5. Use the Increment and Decrement Keys to change the data. The flashing numeral can be changed.
6. Press the Data Key to save the changed data in memory.
flash.
To move to the next digit, press the Shift Key.
Positioning data includes the following data settings: position, speed, acceleration/de-
celeration, and operation mode. (The acceleration/deceleration and operation mode
selection settings are not made for position control by direct input.)
Setting Positioning Data (PTP Data, Direct Input)
Go to the User Parameter Edit Mode.
Display the pertinent parameter number.
Display the parameter contents (data).
Enable the data change.
Change the data.
Save the data in memory.
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
. . . . . . . .
. . . . . . .
. . . . .
to Pd64 ).
Mode Key
Increment Key, Decrement Key,
Increment Key +Data Key, Decre-
ment Key + Data Key
Increment Key
Data Key + Shift Key
Increment Key, Decrement Key,
Shift Key
Data Key
Chapter 3
) desired.

Related parts for R88A-CAU015S